Evidence map›Paper›PMID 35857252›Full record

ArticleMedical & biological engineering & computing2022

Evaluating the dynamic behaviour of bone anchored hearing aids using a finite element model and its applications to implant stability assessment.

Mostafa Mohamed, Lindsey Westover

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Mostafa MohamedUniversity of Alberta, Edmonton, AB, T6G 1H9, Canada. mostafa5@ualberta.ca.ORCID http://orcid.org/0000-0001-5082-4823
Lindsey WestoverUniversity of Alberta, Edmonton, AB, T6G 1H9, Canada.
University of Alberta · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The dynamic behavior of osseointegrated implants can be used for the non-invasive evaluation of the condition of the bone-implant-interface (BII). The Advanced System for Implant Stability Testing (ASIST) is a vibration measurement system that relies on an impact technique and an analytical model to compute the interface stiffness and the ASIST stability coefficient ([Formula: see text]). The objective of this work is to develop a finite element (FE) model capable of capturing the dynamic behaviour of the bone-anchored hearing aid under the ASIST loading condition. The model was validated with previously collected in vitro and in vivo data which were compared to the model's acceleration responses and [Formula: see text] scores. Similar acceleration responses were obtained, and the maximum absolute differences in [Formula: see text] scores between the FE model and the in vitro and in vivo data were 1.15% and 5.48% respectively. The model was then used to show the existence of a relationship between the rod's acceleration response and the BII stress field. Finally, the model was used to interpret the factors that affect the stiffness parameters of the ASIST analytical model. The interface stiffness and the system's dynamic properties were more influenced ([Formula: see text]) by the BII material and friction coefficient compared to the implant geometry. In this work, a finite element model of the bone anchored hearing aid was used to simulate the dynamic behaviour of the bone-implant system under the ASIST's loading conditions. The model was first validated with previously collected experimental and clinical results. The validated model was then used to study the relationship between the impact rod's acceleration response and the response at the bone implant interface. Finally, the model was used to formulate a better understanding on the influencing factors on the interface stiffness.

Indexed as

Dental ImplantsHearing AidsBone and BonesBone-Implant InterfaceFinite Element AnalysisOsseointegrationProstheses and ImplantsStress, MechanicalDental ImplantsFinite element modellingImplant dynamic responseImplant stabilityOsseointegration

Identifiers

PMID35857252
OpenAlexW4286209543

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.