ArticleOrthopaedic surgery2022
Design of a New "U"-shaped Staple and Its Clinical Application in Postoperative Ankle Valgus of Congenital Pseudarthrosis of the Tibia in Children.
Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- Comparison of orthofix external fixator combined with vascularized fibula graft versus single segmental femoral lengthening for treating femoral defects ≥ 6 cm: a retrospective study.BMC musculoskeletal disorders · 2025Article
- Spinal sagittal and coronal morphology characteristics in children with short stature.Quantitative imaging in medicine and surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
objectiveThere has been a lack of suitable epiphysis blocking materials due to the characteristics of less tissue coverage and narrow epiphysis in children's distal tibial medial malleolus. Therefore, this study is to investigate the clinical efficacy and safety of a new "U"-shaped staple in the treatment of postoperative ankle valgus of congenital pseudarthrosis of the tibia (CPT).
methodAccording to the inclusion and exclusion criteria, 33 patients with postoperative ankle valgus of CPT were treated with new "U"-shaped staples from May 2013 to September 2019. The deformity of ankle valgus was gradually corrected by implanting a new "U"-shaped staple on the medial side of the distal tibia. Clinical indexes such as the operation time, intraoperative bleeding and hospital stay were observed. Tibiotalar angle was selected as the evaluation index of ankle valgus. American Orthopedic Foot & Ankle Society (AOFAS) scale was used for clinical evaluation of ankle function. The tibiotalar angle, deformity correction rate and complications were evaluated by preoperative, postoperative and last follow-up imaging data. Student's t-test was used for statistical analysis.
resultsThirty-three patients, including 12 males and 21 females were included. All the patients were followed up for at least 14 months, with an average of 35 months. The average operation time was 23 (15-40) min, the average amount of intraoperative bleeding was 7.5 (4-10) mL, and the average hospital stay was 4.2 (3-6) days. The intraoperative tibiotalar angles of all patients were 74.2° ± 4.6°, the tibiotalar angle were 86.8° ± 4.9° when internal fixation was removed, and the tibiotalar angles at the last follow-up were 84.3° ± 5.9°. The average orthopedic rate was 0.68° per month. No patients suffered from serious complications such as screw prolapse, osteomyelitis, wound infection, etc. Postoperative wound pain complications occurred in two patients, which were relieved after conservative treatment. The AOFAS score improved from 46.2 ± 9.4 before the operation to 74.6 ± 5.7 at the last follow-up (P < 0.01). The ankle movement was good without joint stiffness. There was no epiphyseal plate injury after the removal of internal fixation.
conclusionThe new "U"-shaped staple is characterized by simple implantation, low notch, lower risk of fixation failure and close fitting with cortical bone. It is a safe and effective internal fixation system for the treatment of ankle valgus in children.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.