Evidence map›Paper›PMID 35853991›Full record

ArticleScientific reports2022

Comparison of three imaging and navigation systems regarding accuracy of pedicle screw placement in a sawbone model.

Nils Beisemann, Jula Gierse, Eric Mandelka, Frank Hassel, Paul A Grützner, Jochen Franke, Sven Y Vetter

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nils BeisemannResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Berufsgenossenschaftliche Unfallklinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Jula GierseResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Berufsgenossenschaftliche Unfallklinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Eric MandelkaResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Berufsgenossenschaftliche Unfallklinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Frank HasselDepartment of Spine Surgery, Loretto Hospital, Mercystrasse 6, 79100, Freiburg im Breisgau, Germany.
Paul A GrütznerResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Berufsgenossenschaftliche Unfallklinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Jochen FrankeResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Berufsgenossenschaftliche Unfallklinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Sven Y VetterResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Berufsgenossenschaftliche Unfallklinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany. sven.vetter@bgu-ludwigshafen.de.ORCID 0000-0001-8024-9276

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

3D-navigated pedicle screw placement is increasingly performed as the accuracy has been shown to be considerably higher compared to fluoroscopy-guidance. While different imaging and navigation devices can be used, there are few studies comparing these under similar conditions. Thus, the objective of this study was to compare the accuracy of two combinations most used in the literature for spinal navigation and a recently approved combination of imaging device and navigation system. With each combination of imaging system and navigation interface, 160 navigated screws were placed percutaneously in spine levels T11-S1 in ten artificial spine models. 470 screws were included in the final evaluation. Two blinded observers classified screw placement according to the Gertzbein Robbins grading system. Grades A and B were considered acceptable and Grades C-E unacceptable. Weighted kappa was used to calculate reliability between the observers. Mean accuracy was 94.9% (149/157) for iCT/Curve, 97.5% (154/158) for C-arm CBCT/Pulse and 89.0% for CBCT/StealthStation (138/155). The differences between the different combinations were not statistically significant except for the comparison of C-arm CBCT/Pulse and CBCT/StealthStation (p = 0.003). Relevant perforations of the medial pedicle wall were only seen in the CBCT group. Weighted interrater reliability was found to be 0.896 for iCT, 0.424 for C-arm CBCT and 0.709 for CBCT. Under quasi-identical conditions, higher screw accuracy was achieved with the combinations iCT/Curve and C-arm CBCT/Pulse compared with CBCT/StealthStation. However, the exact reasons for the difference in accuracy remain unclear. Weighted interrater reliability for Gertzbein Robbins grading was moderate for C-arm CBCT, substantial for CBCT and almost perfect for iCT.

Indexed as

Pedicle ScrewsSpinal FusionSurgery, Computer-AssistedFluoroscopyReproducibility of ResultsSpine

Identifiers

PMID35853991
PMCPMC9296669

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.