Evidence map›Paper›PMID 35852654›Full record

ArticleInternational orthopaedics2022

Should cannulated screws be removed after a femoral neck fracture has healed, and how? A finite element analysis of the femur before and after cannulated screw removal.

Le Wu, Jun Sun, Nan Fang, Qing Peng, Shuo Gao, Lifeng Liu

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Le Wu *Department of Trauma Orthopaedics, Shanghai East Hospital, Tongji University School of Medicine, 150 Jimo Road, Shanghai, China.
Jun Sun *Department of Trauma Orthopaedics, Shanghai East Hospital, Tongji University School of Medicine, 150 Jimo Road, Shanghai, China.
Nan FangDepartment of Trauma Orthopaedics, Shanghai East Hospital, Tongji University School of Medicine, 150 Jimo Road, Shanghai, China.
Qing PengDepartment of Trauma Orthopaedics, Shanghai East Hospital, Tongji University School of Medicine, 150 Jimo Road, Shanghai, China.
Shuo GaoDepartment of Trauma Orthopaedics, Shanghai East Hospital, Tongji University School of Medicine, 150 Jimo Road, Shanghai, China.
Lifeng LiuDepartment of Trauma Orthopaedics, Shanghai East Hospital, Tongji University School of Medicine, 150 Jimo Road, Shanghai, China. liulifengxy@163.com.ORCID http://orcid.org/0000-0002-1516-0213
Shanghai East Hospital · CN

Funding

the clinical peak discipline construction project of Shanghai Pudong new area PWYgf2018-05the training project of academic leaders of health and family planning committee of Shanghai Pudong new area PWRd2019-09
6 · The paper itself

Abstract

purposeThe removal of three inverted triangular parallel cannulated screws after the femoral neck fracture healing is sometimes accompanied by osteonecrosis of the femoral head (ONFH) or its refracture. The purpose of this study was to determine the biomechanical changes of the femur before and after the screw removal using a finite element analysis.

methodsThe CT data of the femurs were obtained from a 69-year-old healthy female to establish the femur models. The established finite element models consisted of N, C, and R groups: N group, the normal femur; C group (to simulate the femoral neck fracture healing after the internal fixation), the normal femur with three inverted triangular parallel cannulated screws (C1) or with two upper parallel screws (C2). For the R1 or R2 groups, the screws in the model of the C1 or C2 individuals were gradually removed in seven or three types of different screw combinations, respectively. The stresses and displacements of the femur were determined.

results(1) Compared with the N group, a uniform stress distribution was stopped by the addition of three screws in the C1 group; in contrast, all screw removals resulted in the stress concentration on the screw holes and the disappearance of stress shielding. Moreover, the average stress of the femoral head in C1 group increased by 37.85%, while that of the femoral neck decreased by 23.03%. (2) Compared with the C1 group, while only the lowest femoral calcar screw was removed, there was a similar stress distribution in the proximal femur, and the average stress of the femoral head increased only by 0.35% although that of the femoral neck increased by 63.62%; however, removal by any other means resulted in a significant stress concentration in the proximal femur and a significant increase in the average stresses of the femoral head and neck (5.96-40.95% and 12.82-75.46%, respectively). (3) Compared with the N or C1 group, there was a significant stress concentration on the screws and its surrounding proximal femur in the C2 group. (4) Compared with the C2 group, the simultaneous removal of two upper screws not only did not cause a significant stress concentration on the proximal femur but also significantly reduced the average stresses of the femoral head and neck by 87.49% and 65.51% respectively. On the contrary, the gradual removal of two screws caused a significant stress concentration on the screw and its surrounding proximal femur although the average stresses of the femoral head and neck decreased by 88.79-89.06% and 67.00-67.22%, respectively. (5) Compared with the N group, the average displacements of the femoral head and neck in the C1 group increased only by 3.12% and 3.37%, respectively. Additionally, compared with the C1 group, while three, two, or one screw was simultaneously removed, the average displacements of the femoral head and neck only fluctuated - 5.51-1.65% and 1.78-9.03%, respectively.

conclusionsResidual internal fixation after femoral neck fracture healing may lead to stress concentration on screws and stress shielding around screws. The first removal of the lowest femoral calcar screw and then the second removal of two upper residual screws have a minimum effect on the stress concentration on the proximal femur and the average stress on the femoral head. The incorrect screw removal and resulting femoral load may well be closely related to occurrence in ONFH or its refracture.

Indexed as

Femoral Neck FracturesAgedBiomechanical PhenomenaBone ScrewsFemaleFemurFinite Element AnalysisFracture Fixation, InternalHumansBiomechanical effectCannulated screw removalFemoral neck fractureFinite element analysisOsteonecrosis of the femoral head

Identifiers

PMID35852654
OpenAlexW4285796596

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.