Evidence map›Paper›PMID 35852637›Full record

ArticleArchives of microbiology2022

Comparative analysis of specificity and sensitivity between Cobas 6800 system and SARS-CoV-2 rRT-PCR to detect COVID-19 infection in clinical samples.

Simmi Grewal, Mehreen Syed Gurcoo, Shashi Sudhan Sharma

Abstract read
In one paragraph

Article in Archives of microbiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Simmi GrewalDepartment of Microbiology, Government Medical College, Jammu, 180001, Jammu and Kashmir, India.
Mehreen Syed GurcooDepartment of Microbiology, Government Medical College, Jammu, 180001, Jammu and Kashmir, India.
Shashi Sudhan SharmaDepartment of Microbiology, Government Medical College, Jammu, 180001, Jammu and Kashmir, India. vrdlgmc@gmail.com.ORCID http://orcid.org/0000-0002-2427-6058

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fast and reliable testing for the COVID 19 infection is the need of the hour for the development of effective and reliable tools and assays. However, it is difficult to find the performance relativity among all these tests which are poorly understood. In this study, we aimed to evaluate the two different platforms where we determine the difference of sensitivity and specificity between the fully automated analyzer (Roche Diagnostics Cobas 6800 SARS-CoV-2 test) under FDA Emergency Use Authorization (EUA) and the laboratory designed test (SARS-CoV-2 rRT-PCR) based on the protocol developed by ICMR (Indian Council for Medical Research). The study was conducted for individual samples. We performed our study with two different approaches, first with validation method consisting of 188 samples (2 batches) on cobas 6800 instrument (Roche Molecular Systems, Branchburg, NJ) soon after we received US FDA EUA on 1 June 2021, all these samples were tested earlier with laboratory designed tests on 25th and 26th May 2021. Over all agreement between the two tests is of 88% and the coefficient of agreement between the two testing platform Cohen'sκ coefficient was found to be 0.76 (95% CI, 2.5897-13.4103) suggesting the substantial agreement between the two platforms. However, in some of the cases, both tests have shown a little disagreement. An overall discordance rate between two systems was found 11.1%. The difference may be due to the limit of detection, variation in the sequences of the primer design or may be due to other factors depicting the importance of comparing the two platforms used in the testing for SARS-CoV-2. Second approach includes head to head evaluation which comprises 1631 samples showed overall agreement of 99% and kappa value of 0.98. These results showed that cobas is effective and reliable assay for the detection of SARS-CoV-2 infection.

Indexed as

COVID-19SARS-CoV-2Clinical Laboratory TechniquesCOVID-19 TestingHumansMolecular Diagnostic TechniquesReverse Transcriptase Polymerase Chain ReactionSensitivity and SpecificityCOBAS 6800Molecular diagnosticrRT-PCRViral load

Identifiers

PMID35852637
PMCPMC9295087

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials