ArticleJoint diseases and related surgery2022
The round femoral stem provides a similar clinical outcome but more serious proximal stress shielding compared to the rectangular stem in cementless total hip arthroplasty without a shortening osteotomy in patients with Crowe type 2 or 3 hip dysplasia.
Article in Joint diseases and related surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- 'THA for DDH: replacement principles and techniques - femoral side'.EFORT open reviews · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThis study aims to compare clinical and radiological follow-up results of a rectangular (SL-Plus®) or a round (Synergy®) femoral component in patients with Crowe type 2 or 3 hip dysplasia operated with total hip arthroplasty (THA) without a shortening osteotomy. PATIENTS AND
methodsBetween January 2012 and December 2017, a total of 34 hips of 30 female patients (mean age: 42.9±11.6 years; range, 24 to 66 years) were retrospectively analyzed. All patients were evaluated using the Harris Hip Score (HHS) and Visual Analog Scale (VAS) for pain pre- and postoperatively. Intra- and postoperative complications were noted. Evaluation criteria included leg length discrepancy, stem subsidence, bone atrophy or hypertrophy around the stem according to Gruen zones, operative time, and intraoperative blood loss. Correlation analysis of radiological, clinical findings, and stem size was performed.
resultsThe mean follow-up was 61.3±27.2 months. The mean postoperative HHS was 89.3±6.2 vs. 93.1±9.1, and the mean VAS score 1±0.6 vs. 1±0.8 in round and rectangular stem groups at the final follow-up. No significant differences were detected between the groups in any of the evaluated parameters, except for a more severe degree of stress shielding observed in the round stem group. Round stem size was positively correlated with a more severe stress shielding (r=0.55, p=0.020). No patient had to be revised during the follow-up period. The overall complication rate was 9%.
conclusionSuccessful and comparable results can be obtained with cementless THA in patients with high riding dysplastic hips implanting either of the femoral components, a rectangular or a round stem. Although the round stem was associated with more common proximal stress shielding, this was not associated with worse clinical outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.