ArticleJoint diseases and related surgery2022
Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach.
Article in Joint diseases and related surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 10 citations in OpenAlex.
- Anterior Cortical Reference Technique for Sagittal Positioning of Distal Femoral Resection in Kinematic Alignment Total Knee Arthroplasty.Clinics in orthopedic surgery · 2026Article
- Accuracy of digital inclinometers for measuring knee extension during total knee arthroplasty: comparison with visual estimation and computer navigation.Arthroplasty (London, England) · 2026Article
- Proposing a precision-enhancing method for sagittal plane alignment during total knee arthroplasty.BMC musculoskeletal disorders · 2025Article
- Effects of preoperative valgus deformity in patients undergoing neutrally aligned total knee arthroplasty: A retrospective cohort study with a minimum five-year follow-up.Joint diseases and related surgery · 2024Article
- Gerdy's tubercle as a novel anatomical landmark for the proximal tibial cut in total knee arthroplasty.Joint diseases and related surgery · 2024Article
- Phenotyping of the Turkish population according to Coronal Plane Alignment of the Knee classification: A retrospective cross-sectional study.Joint diseases and related surgery · 2024Article
- Does sagittal alignment of the femoral component have an impact on radiological loosening and functional results in revision knee arthroplasty?Joint diseases and related surgery · 2023Article
- Total versus unicompartmental knee arthroplasty.Joint diseases and related surgery · 2023Article
- Total knee arthroplasty in patients with marked coronal femoral bowing deformities: A systematic review.Tzu chi medical journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThe aim of this study was to simulate different entry points and investigate potential angulation errors of the intramedullary device and resulting changes in the distal femoral cut using a computer-aided design (CAD) approach. MATERIALS AND
methodsWe used a CAD approach to simulate various distal femoral entry points for intramedullary instrumentation. Simulations were performed on (i) a commercially available three-dimensional (3D) CAD model of a human femur (DigitalFemur) and (ii) a digital 3D model of an analogue large femur model produced using a coordinate measuring machine (FaroFemur). Divergent insertion points medial, lateral, anterior and posterior to the ideal position were simulated. Angulation deviations of the resulting positions of the intramedullary rod were measured and changes in the anatomical-mechanical axis angle were calculated. Differences between the two simulation models were quantified.
resultsThe ideal entry point in the FaroFemur was 9.9 mm anterior and 4.3 mm medial to the apex of the intercondylar notch, and 9.2 mm anterior and 3.6 mm medial in the DigitalFemur. A medial entry point increased the angle between the anatomical femoral axis and the alignment rod in the FaroFemur and DigitalFemur (with 5 mm displacement 2.510° and 2.363°, respectively; with 10 mm displacement 3.239° and 3.283°, respectively). In contrast, a lateral entry point decreased the angle between the anatomical femoral axis and the alignment rod (with 5 mm displacement 2.267° and 2.262°, respectively; with 10 mm displacement 3.158° and 3.731°, respectively). An anterior entry point changed the angle between the anatomical femoral axis and the alignment rod towards extension (1.802° in the FaroFemur; 2.142° in the DigitalFemur), while a posterior entry point generated a deviation toward flexion (2.045° in the FaroFemur; 2.055° in the DigitalFemur). The mean difference between the two models was 0.108±0.121° with the highest difference for anterior displacement.
conclusionMinor deviations of the entry point for intramedullary instrumentation during total knee arthroplasty can result in malalignment of several degrees.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.