ArticleMedical physics2022
Estimating the accuracy of dual energy chest radiography for coronary calcium detection with lateral or anteroposterior orientations.
Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Evaluation of algorithmic requirements for clinical application of material decomposition using a multi-layer flat panel detector.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Synthesizing High-Resolution Dual-Energy Radiographs from Coronary Artery Calcium CT Images.Proceedings of SPIE--the International Society for Optical Engineering · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
Abstract
purposeCoronary artery calcium (CAC) scoring with CT has been studied as a risk stratification tool for cardiovascular disease. However, concerns remain from the radiation dose, economic expense, and incidental findings associated with this exam. Dual energy chest X-ray (DE CXR) has been proposed as an alternative, but validation of this technique remains limited. The purpose of this work was twofold: first, to estimate the sensitivity and specificity of DE CXR using simulation of patient datasets in a CAC screening cohort; second, to assess if sensitivity and specificity could be improved using a lateral instead of an anteroposterior (AP) orientation.
methodsWe started from a cohort of 73 CAC scoring CT exams after exclusions for metal wires, data truncation, or with age outside 40-75 years. The fraction of CT CAC scores in the validation set of 0, 1-99, 100-299, and 300+ were 36, 25, 14, and 26%, respectively. CT datasets were decomposed on a voxel-by-voxel basis into mixtures of water and calcium according to CT number. DE CXR images were simulated using polyenergetic forward projection with scatter estimated from Monte Carlo. We assumed a technique of 60 and 120 kVp for the dual energy acquisition. The tube current was scaled such that the estimated radiation dose from DE CXR was 10 times less than CAC scoring CT. Patient motion was not simulated. Two readers read the validation set in a blinded, randomized fashion, and estimated the amount of CAC in each DE CXR image using a semiquantitative 4-point scale. Although patients present on a spectrum of CAC severity, in the primary analysis, sensitivity and specificity were calculated by dichotomizing patients into two categories of CT CAC (Agatston) scores of either 0-99 or 100+.
resultsFrom the lateral orientation, average sensitivity between two readers was 69% (range, 69-69%), specificity was 85% (range, 84-86%), and area under the curve (AUC) was 0.81 (range, 0.80-0.81). From the AP orientation, average sensitivity was 35% (range, 31-38%), average specificity was 70% (range, 66-73%), and AUC was 0.54 (range, 0.53-0.55). Reader DE CXR scores agreed within 1 point of the 4-point scale on 97% of ratings from the lateral orientation and 80% from the AP orientation. From the lateral orientation, AUC increased when considering higher CT CAC score thresholds as disease positive; for thresholds of 1+, 300+, and 1000+, average AUC was 0.72, 0.81, and 0.92, respectively. From the AP orientation, AUC was 0.57, 0.55, and 0.61, respectively.
conclusionsDE CXR for CAC scoring may have higher diagnostic accuracy when acquired from the lateral orientation. The sensitivity and specificity of lateral DE CXR, when combined with its modest cost and radiation dose, suggest a possible role for this technique in screening coronary calcium in lower risk individuals. These estimates of diagnostic accuracy are derived from simulation of patient datasets and have not been corroborated with experimental or clinical images.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.