ArticleJournal of applied clinical medical physics2022
Quality assurance and long-term stability of a novel 3-in-1 X-ray system for brachytherapy.
Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Approaches to needle navigation in interstitial brachytherapy using infrared tracking and radiography.Journal of applied clinical medical physics · 2026Article
- Assessment of needle bending and tracking requirements for optimized needle placement in combined intracavitary/interstitial gynecologic brachytherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026Article
- Evaluation of image quality in mobile cone-beam CT with dose modulation using automatic exposure control: A phantom study.Journal of applied clinical medical physics · 2025Article
- Initial needle tracking with the first standalone combined infrared camera - CT system for brachytherapy-analysis of tracking accuracy and uncertainties.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025Article
- Is model-based dose calculation based on cone-beam computed tomography suitable for adaptive treatment planning in brachytherapy?Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025Article
- Establishing an intraoperative, mobile CBCT-based workflow for gynecologic brachytherapy: primary experience and benefit assessment.Frontiers in oncology · 2025Article
- First implementation of an innovative infra-red camera system integrated into a mobile CBCT scanner for applicator tracking in brachytherapy-Initial performance characterization.Journal of applied clinical medical physics · 2024Article
- Quality assurance and long-term stability of a novel 3-in-1 X-ray system for brachytherapy.Journal of applied clinical medical physics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeA novel, mobile 3-in-1 X-ray system featuring radiography, fluoroscopy, and cone-beam computed tomography (CBCT) has been launched for brachytherapy recently. Currently, there is no quality assurance (QA) procedure explicitly applicable to this system equipped with innovative technologies such as dynamic jaws and motorized lasers. We developed a dedicated QA procedure and, based on its performance for a duration of 6 months, provide an assessment of the device's stability over time.
methodsWith the developed QA procedure, we assessed the system's planar and CBCT-imaging performance by investigating geometric accuracy, CT-number stability, contrast-noise-ratio, uniformity, spatial resolution, low-contrast detectability, dynamic range, and X-ray exposure using dedicated phantoms. Furthermore, we evaluated geometric stability by using the flexmap-approach and investigated the device's laser- and jaw-positioning accuracy with an in-house test phantom. CBCT- and planar-imaging protocols for pelvis, breast, and abdomen imaging were examined.
resultsPlanar- and CBCT-imaging performances were widely stable with a geometric accuracy ≤1 mm, CT-number stability of up to 46 HU, and uniformity variations of up to 48 HU over time. For planar imaging, low-contrast detectability and dynamic range exceeded current recommendations. Although geometric stability was considered tolerable, partly substantial positioning inaccuracies of up to more than 120 mm and -13 mm were obtained for lasers and jaws, respectively. X-ray exposure showed small variations of ≤0.56 μGy and ≤0.76 mGy for planar- and CBCT-imaging, respectively. The conductance of the QA procedure allowed a smooth evaluation of the system's overall performance.
conclusionWe developed a QA workflow for a novel 3-in-1 X-ray system allowing to assess the device's imaging and hardware performance. The system showed in general a reasonable imaging performance and stability over time, whereas improvements regarding laser and jaw accuracy are strictly required.