Evidence map›Paper›PMID 35847807›Full record

ArticleFrontiers in medicine2022

A Tapered Cuff Tracheal Tube Decreases the Need for Cuff Pressure Adjustment After Surgical Retraction During Anterior Cervical Spine Surgery: A Randomized Controlled, Double-Blind Trial.

Yi-Shiuan Li, Elise Chia-Hui Tan, Yueh-Ju Tsai, Mercedes Susan Mandell, Shiang-Suo Huang, Ting-Yun Chiang, Wen-Cheng Huang, Wen-Kuei Chang, Ya-Chun Chu

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Frontiers in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04591769 (Cuff Pressure During Surgical Retractor Splay and Postoperative Voice Outcome After Anterior Cervical Spine Surgery), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04591769 nacompletednot on this map

Cuff Pressure During Surgical Retractor Splay and Postoperative Voice Outcome After Anterior Cervical Spine Surgery: Comparison Between Tapered-shaped and Conventional Cylindrical-shaped Endotracheal Tube

TypeinterventionalSponsorTaipei Veterans General Hospital, TaiwanRan2020 to 2021Enrolled80ConditionsIntubation, Intratracheal, Pain, Postoperative, DysphoniaArmsDifferent tracheal tube cuff design
3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Yi-Shiuan LiDepartment of Anesthesiology, Taipei Veterans General Hospital, Taipei City, Taiwan.
Elise Chia-Hui TanNational Research Institute of Chinese Medicine, Ministry of Health and Welfare, Taipei City, Taiwan.
Yueh-Ju TsaiDepartment of Otorhinolaryngology-Head and Neck Surgery, Taipei Veterans General Hospital, Taipei City, Taiwan.
Mercedes Susan MandellDepartment of Anesthesiology, University of Colorado, Aurora, CO, United States.
Shiang-Suo HuangDepartment of Pharmacology, Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan.
Ting-Yun ChiangDepartment of Anesthesiology, Taipei Veterans General Hospital, Taipei City, Taiwan.
Wen-Cheng HuangSchool of Medicine, National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
Wen-Kuei ChangDepartment of Anesthesiology, Taipei Veterans General Hospital, Taipei City, Taiwan.
Ya-Chun ChuDepartment of Anesthesiology, Taipei Veterans General Hospital, Taipei City, Taiwan.
Taipei Veterans General Hospital · TWNational Yang Ming Chiao Tung University · TWChung Shan Medical University Hospital · TWMemorial Hermann–Texas Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Surgical retraction to expose the vertebrae during anterior cervical spine surgery increases tracheal tube cuff pressure and may worsen postoperative sore throat and dysphonia. This randomized double-blind study investigated the effect of cuff shape on intraoperative cuff pressure and postoperative sore throat and dysphonia. Methods: Eighty patients were randomized to tracheal intubation with a tapered cuff or a conventional cylindrical high-volume low-pressure cuff (control) during anesthesia. Intraoperative cuff pressures were compared. The primary outcome was the incidence of pressure adjustment needed when the cuff pressure increased to > 25 mm Hg after surgical retraction. The secondary outcome was the incidence of postoperative sore throat and dysphonia. Results: The incidence of pressure adjustment after surgical retraction was significantly lower in the tapered group than in the control group (13% vs. 48%; Conclusion: A tapered cuff tracheal tube decreased the need for the adjustment of cuff pressure after surgical retraction during anterior cervical spine surgery, thereby avoiding intraoperative pressure increase. It also has a better outcome in terms of dysphonia. Clinical Trial Registration: [www.clinicaltrials.gov], identifier [NCT04591769].

Indexed as

anterior cervical spine surgerydysphoniaGRBAStapered cufftracheal tube cuff pressure

Identifiers

PMID35847807
PMCPMC9276934
OpenAlexW4283697676

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials