ArticleAdvances in radiation oncology
Less Time Is Less Motion: Analysis of Practical Efficiencies Gained With a Modified Workflow Integrating Planar kV Midimaging With CBCT for Spine Stereotactic Body Radiation Therapy.
Article in Advances in radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Role of Metastasis-Directed Therapy in Genitourinary Cancers.Current treatment options in oncology · 2024Review
- A Prospective Study Assessing the Efficacy and Toxicity of Stereotactic Body Radiation Therapy for Oligometastatic Bone Metastases.Advances in radiation oncology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Our purpose was to optimize an image guided radiation therapy (IGRT) workflow to achieve practical setup accuracy in spine stereotactic body radiation therapy (SBRT). We assessed the time-saving efficiencies gained from incorporating planar kV midimaging as a surrogate for cone beam computed tomography (CBCT) for intrafraction motion monitoring. Methods and Materials: We selected 5 thoracic spine SBRT patients treated in 5 fractions and analyzed patient shifts captured by a modified IGRT workflow using planar kV midimaging integrated with CBCT to maintain a tolerance of 1 mm and 1°. We determined the frequency at which kV midimaging captured intrafraction motion as validated on repeat CBCT and assessed the potential time and dosimetric advantages of our modified IGRT workflow. Results: Patient motion, detected as out-of-tolerance shifts on planar kV midimaging, occurred during 6 of 25 fractions (24%) and were validated on repeat CBCT 100% of the time. Observed intrafraction absolute shifts (mean ± standard deviation) for the 25 fractions were 0.39 ± 0.21, 0.56 ± 0.22, and 0.45 ± 0.21 mm for lateral-longitude-vertical translations and 0.38 ± 0.12°, 0.32 ± 0.09°, and 0.47 ± 0.14° for pitch-roll-yaw rotation, which if uncorrected, could have significantly affected target coverage and increased spinal cord dose. The average times for pretreatment imaging, midtreatment verification, and total treatment time were 8.94, 2.81, and 16.21 minutes. Our modified IGRT workflow reduced the total number of CBCTs required from 120 to 35 (70%) and imaging dose from 126.2 to 43.4 cGy (65.6%) while maintaining high fidelity for our patient population. Conclusions: Accurate patient positioning was effectively achieved with use of multiple 2-dimensional-3-dimensional kV images and an average of 1 verification CBCT scan per fraction. Integration of planar kV midimaging can effectively reduce treatment time associated with spine SBRT delivery and minimize the potential dosimetric effect of intrafraction motion on target coverage and spinal cord dose.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.