Evidence map›Paper›PMID 35842636›Full record

ArticleRadiation oncology (London, England)2022

Assessment of dose perturbations for metal stent in photon and proton radiotherapy plans for hepatocellular carcinoma.

Boram Lee, Sungkoo Cho, Hee Chul Park, Sang-Won Kang, Jae-Sung Kim, Jin-Beom Chung

Open access · goldAbstract read
In one paragraph

Article in Radiation oncology (London, England), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Boram LeeDepartment of Radiation Oncology, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620, Seongnam, Korea.
Sungkoo ChoDepartment of Radiation Oncology, Samsung Medical Center, Seoul, South Korea.
Hee Chul ParkDepartment of Radiation Oncology, Samsung Medical Center, Seoul, South Korea.
Sang-Won KangDepartment of Radiation Oncology, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620, Seongnam, Korea.
Jae-Sung KimDepartment of Radiation Oncology, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620, Seongnam, Korea.
Jin-Beom ChungDepartment of Radiation Oncology, Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620, Seongnam, Korea. jbchung1213@gmail.com.ORCID http://orcid.org/0000-0003-2668-3906
Seoul National University Bundang Hospital · KRSamsung Medical Center · KR

Funding

National Research Foundation of Korea (NRF) grant funded by the Korea government No. 2022R1C1C1006840
6 · The paper itself

Abstract

backgroundThe present study aimed to investigate the dosimetric impact of metal stent for photon and proton treatment plans in hepatocellular carcinoma.

methodsWith computed tomography data of a water-equivalent solid phantom, dose perturbation caused by a metal stent included in the photon and proton treatment of hepatocellular carcinoma was evaluated by comparing Eclipse and RayStation treatment planning system (TPS) to a Monte Carlo (MC) based dose calculator. Photon and proton plans were created with anterior-posterior/posterior-anterior (AP/PA) fields using a 6 MV beam and AP/PA fields of a wobbling beam using 150 MeV and a 10 cm ridge filter. The difference in dose distributions and dosimetric parameters were compared depending on the stent's positions (the bile duct (GB) and intestinal tract (GI)) and angles (0°, 45°, and 90°). Additionally, the dose variation in the target volume including the stent was comparatively evaluated through dose volume histogram (DVH) analysis. And the comparison of clinical cases was carried out in the same way.

resultsPercentage differences in the dosimetric parameters calculated by MC ranged from - 7.0 to 3.9% for the photon plan and - 33.7 to 4.3% for the proton plan, depending on the angle at which the GB and GI stents were placed, compared to those without the stent. The maximum difference was observed at the minimum dose (D

conclusionsDose perturbations within the target volume due to the presence of the metal stent were not observed in the TPS calculations for photon and proton beams, but MC was used to confirm that there are dose variations within the target volume. The MC results found that delivery of the treatment beam avoiding the stent was the best method to prevent target volume underdose.

Indexed as

Carcinoma, HepatocellularLiver NeoplasmsProton TherapyRadiotherapy, Intensity-ModulatedAlgorithmsHumansMonte Carlo MethodPhantoms, ImagingProtonsRadiotherapy DosageRadiotherapy Planning, Computer-AssistedProtonsHepatocellular carcinomaMetal stentMonte Carlo simulationPhotonProton

Identifiers

PMID35842636
PMCPMC9288675
OpenAlexW4285586738

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.