ArticleBMC ophthalmology2022
A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study.
Article in BMC ophthalmology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo establish and verify the accuracy and reliability of a sulcus-to-sulcus diameter (STS) prediction model.
methodsIn this retrospective study, the prediction formula was established with the data from 1466 eyes from 733 subjects from July 2020 to April 2021 and verified with the data from 278 eyes from 139 subjects between May 2021 and June 2021. Each subject was measured with a Pentacam, IOLMaster 700, OPD-Scan III, and ultrasound biomicroscope. The prediction formulas were established with multiple linear regression, and intergroup correlation coefficients (ICCs) and Bland-Altman tests were used to assess the agreement between the predicted and actual STS (actual STS was measured by UBM).
resultsThe explanatory variables relevant to the horizontal STS (STSH) were the Pentacam white-to-white diameter (WTWP; standardized partial regression coefficient [β] = 0.330; p < 0.001), the flat K value (β = -0.211; p < 0.001), and the anterior corneal diameter (ACD) (β = 0.178; p < 0.001). The corresponding multiple regression equation was : STSH (mm) = 8.061 + 0.510 × WTWP - 0.090 × Flat K value + 0.430 × ACD. The explanatory variables relevant to the vertical STS (STSV) were the WTWP (β = 0.435; p < 0.001), the steep K value (β = -0.271; p < 0.001), and the ACD (β = 0.187; p < 0.001). The corresponding multiple regression equation was : STSV (mm) = 8.540 + 0.492 × WTWP - 0.075 × Steep K value + 0.329 × ACD. The bias of the predicted to the actual STSH was - 0.021, with 95% limits of agreement (95% LoA) from - 0.499 to 0.457. The bias of the predicted to the actual STSV was 0.057, with 95% LoA from - 0.462 to 0.575. The ICC was 0.883 between the predicted and actual STSH and 0.859 between the predicted and actual STSV.
conclusionsThe Pentacam-measured WTW, the K value and the ACD are important for predicting the STS diameter. The prediction model has good accuracy and reliability.
trial registrationNot applicable.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.