ArticlePloS one2022
Iodine images in dual energy CT: A monocentric study benchmarking quantitative iodine concentration values of the healthy liver.
Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 11 citations in OpenAlex.
- Nonprewhitening model observers in the Fourier and spatial domain: a comparison of predictions for iterative and deep learning reconstruction in computed tomography.Radiation protection dosimetry · 2026Article
- Truth-based physics informed estimation of material composition in spectral CT in terms of density and effective atomic number.Physics in medicine and biology · 2026Article
- Spectral CT quantitative parameters for predicting complete ablation after radiofrequency ablation in liver tumors: a retrospective study.Frontiers in oncology · 2026Article
- Photon-Counting Computed Tomography-Based Hepatic iron Quantification Using a Tungsten-Based Contrast Agent.Investigative radiology · 2025Article
- A practical approach to the spatial-domain calculation of nonprewhitening model observers in computed tomography.Medical physics · 2025Article
- Performance of iodine quantification through high-pitch dual-source photon-counting CT: a phantom study.Japanese journal of radiology · 2025Article
- Standardization of Dual-Energy CT Iodine Uptake of the Abdomen and Pelvis: Defining Reference Values in a Big Data Cohort.Diagnostics (Basel, Switzerland) · 2024Article
- Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Dual energy computed tomography (DECT) allows the quantification of specific materials such as iodine contrast agent in human body tissue, potentially providing additional diagnostic data. Yet full diagnostic value can only be achieved if physiological normal values for iodine concentrations are known. We retrospectively evaluated abdominal DECT scans of 105 patients with healthy liver between March and August 2018 (age 17 to 86 years, 43 female and 62 male). The iodine concentrations within ROIs of the liver parenchyma as well as of the abdominal aorta and main portal vein were obtained. We evaluated the absolute iodine concentration and blood-normalized iodine concentrations relating the measured iodine concentration of the liver parenchyma to those of the supplying vessels. The influence of age and gender on the iodine uptake was assessed. The absolute iodine concentration was significantly different for the male and female cohort, but the difference was eliminated by the blood-normalized values. The average blood-normalized iodine concentrations were 2.107 mg/ml (+/- 0.322 mg/ml), 2.125 mg/ml (+/- 0.426 mg/ml) and 2.103 mg/ml (+/- 0.317 mg/ml) for the portal vein normalized, aorta normalized and mixed blood normalized iodine concentrations, respectively. A significant negative correlation between the patients' age and the iodine concentration was detected only for the blood-normalized values. A physiological range for iodine concentration in portal venous phase contrast enhanced DECT images can be defined for absolute and blood-normalized values. Deviations of blood-normalized iodine concentration values might be a robust biomarker for diagnostic evaluation. Patient age but not the gender influences the blood-normalized iodine concentrations in healthy liver parenchyma.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials