Performance comparison of quantitative metrics for analysis of in vivo Cherenkov imaging incident detection during radiotherapy.

Savannah M Decker, Daniel A Alexander, Petr Bruza, Rongxiao Zhang, Erli Chen, Lesley A Jarvis, David J Gladstone, Brian W Pogue

Abstract read
In one paragraph

Article in The British journal of radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Imaging and characterization of optical emission fromPhysics in medicine and biology · 2024
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Savannah M DeckerThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States.ORCID 0000-0002-0733-0278
Daniel A AlexanderThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States.
Petr BruzaThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States.
Rongxiao ZhangThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States.
Erli ChenCheshire Medical Center, Keene NH, United States.
Lesley A JarvisGeisel School of Medicine, Dartmouth College, Hanover, New Hampshire, United States.
David J GladstoneThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States.
Brian W PogueThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, United States.

Funding

Translational Engineering in Cancer (TEC)P30CA023108 · NCI · DARTMOUTH COLLEGE · PI Steven D Leach · 1985 to 2026
$91.3M
OPTICAL CHERENKOV IMAGING DOSIMETRY IN HUMAN RADIOTHERAPYR01EB023909 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI GLADSTONE, DAVID J., JARVIS, LESLEY A · 2017 to 2024
$4.4M
NCI NIH HHS P30 CA023108NIBIB NIH HHS R01 EB023909
6 · The paper itself

Abstract

objectivesExamine the responses of multiple image similarity metrics to detect patient positioning errors in radiotherapy observed through Cherenkov imaging, which may be used to optimize automated incident detection.

methodsAn anthropomorphic phantom mimicking patient vasculature, a biological marker seen in Cherenkov images, was simulated for a breast radiotherapy treatment. The phantom was systematically shifted in each translational direction, and Cherenkov images were captured during treatment delivery at each step. The responses of mutual information (MI) and the γ passing rate (%GP) were compared to that of existing field-shape matching image metrics, the Dice coefficient, and mean distance to conformity (MDC). Patient images containing other incidents were analyzed to verify the best detection algorithm for different incident types.

resultsPositional shifts in all directions were registered by both MI and %GP, degrading monotonically as the shifts increased. Shifts in intensity, which may result from erythema or bolus-tissue air gaps, were detected most by %GP. However, neither metric detected beam-shape misalignment, such as that caused by dose to unintended areas, as well as currently employed metrics (Dice and MDC).

conclusionsThis study indicates that different radiotherapy incidents may be detected by comparing both inter- and intrafractional Cherenkov images with a corresponding image similarity metric, varying with the type of incident. Future work will involve determining appropriate thresholds per metric for automatic flagging. ADVANCES IN KNOWLEDGE: Classifying different algorithms for the detection of various radiotherapy incidents allows for the development of an automatic flagging system, eliminating the burden of manual review of Cherenkov images.

Indexed as

BenchmarkingRadiotherapy Planning, Computer-AssistedAlgorithmsDiagnostic ImagingHumansPhantoms, Imaging

Identifiers

PMID35834415
PMCPMC10996952

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.