Evidence map›Paper›PMID 35833877›Full record

ArticleAnalytical chemistry2022

Quantum Cascade Laser-Based Vibrational Circular Dichroism Augmented by a Balanced Detection Scheme.

Daniel R Hermann, Georg Ramer, Markus Kitzler-Zeiler, Bernhard Lendl

Abstract read
In one paragraph

Article in Analytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Becoming fully circular facilitated by PAT.Analytical and bioanalytical chemistry · 2025
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Daniel R HermannInstitute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164-UPA, 1060 Vienna, Austria.ORCID 0000-0003-2605-8203
Georg RamerInstitute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164-UPA, 1060 Vienna, Austria.ORCID 0000-0001-8307-5435
Markus Kitzler-ZeilerPhotonics Institute, TU Wien, Gußhausstrasse 27-29, 1040 Vienna, Austria.
Bernhard LendlInstitute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164-UPA, 1060 Vienna, Austria.ORCID 0000-0003-3838-5842

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Vibrational circular dichroism (VCD) constitutes a powerful technique, enabling the determination of the absolute configuration of molecules without the need for specialized reagents. While delivering critical information, VCD signals commonly are several orders of magnitude weaker than classical absorbance signals, which so far necessitated long measurement times to achieve acceptable signal-to-noise ratios (SNRs) in VCD experiments. We present here an improved setup for the measurement of VCD in the range between 5.6 and 6.5 μm. Employing an external cavity quantum cascade laser (EC-QCL) as a high-power light source, we collected spectra with competitive noise levels in less than 5 min. The basis for this improvement was a balanced detection module combined with an optical path catered to VCD measurements. With the stabilization provided by the two-detector setup, noise originating from the laser source could be suppressed effectively. Noise level improvement up to a factor of 4 compared to the classical single detector EC-QCL-VCD could be reported. Compared to commercial Fourier transform infrared (FT-IR) instruments, the presented setup offers measurement time reductions of a factor of at least 6, with comparable noise levels. The applicability of the setup for qualitative and quantitative VCDs was proven. With the comparatively high temporal resolution provided, the monitoring of optically active processes will be possible in future applications.

Indexed as

Lasers, SemiconductorCircular DichroismFourier AnalysisSpectroscopy, Fourier Transform Infrared

Identifiers

PMID35833877
PMCPMC9330291

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.