Evidence map›Paper›PMID 35832849›Full record

ArticleBioMed research international2022

A Modified Deep Learning Framework for Arrhythmia Disease Analysis in Medical Imaging Using Electrocardiogram Signal.

A Anbarasi, T Ravi, V S Manjula, J Brindha, S Saranya, G Ramkumar, R Rathi

RetractedOpen access · hybridAbstract readRetracted Publication
In one paragraph

Article in BioMed research international, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
4.1field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 25 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

A AnbarasiDepartment of Electronics and Communication Engineering, Sathyabama Institute of Science and Technology, Chennai, 600119 Tamil Nadu, India.ORCID https://orcid.org/0000-0002-3501-0386
T RaviDepartment of Electronics and Communication Engineering, Sathyabama Institute of Science and Technology, Chennai, 600119 Tamil Nadu, India.ORCID https://orcid.org/0000-0002-0359-6140
V S ManjulaDepartment of Computer Science and Engineering, KIoT-College of Informatics, Kombolcha, Wollo University, Ethiopia.ORCID https://orcid.org/0000-0003-0308-3289
J BrindhaDepartment of Electronics and Instrumentation Engineering, Panimalar Engineering College, Chennai, 600123 Tamil Nadu, India.ORCID https://orcid.org/0000-0001-5274-9994
S SaranyaDepartment of Electronics and Communication Engineering, Easwari Engineering College, Ramapuram, Chennai, Tamil Nadu, India.ORCID https://orcid.org/0000-0002-3052-0248
G RamkumarDepartment of Electronics and Communication Engineering, Saveetha School of Engineering, SIMATS, Chennai, 602 105 Tamil Nadu, India.ORCID https://orcid.org/0000-0002-3187-9949
R RathiSchool of Information Technology and Engineering, Vellore Institute of Technology, Vellore, 632014 Tamil Nadu, India.ORCID https://orcid.org/0000-0002-3903-2099
Sathyabama Institute of Science and Technology · INSaveetha University · INVellore Institute of Technology University · INWollo University · ET

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Arrhythmias are anomalies in the heartbeat rhythm that occur occasionally in people's lives. These arrhythmias can lead to potentially deadly consequences, putting your life in jeopardy. As a result, arrhythmia identification and classification are an important aspect of cardiac diagnostics. An electrocardiogram (ECG), a recording collecting the heart's pumping activity, is regarded the guideline for catching these abnormal episodes. Nevertheless, because the ECG contains so much data, extracting the crucial data from imagery evaluation becomes extremely difficult. As a result, it is vital to create an effective system for analyzing ECG's massive amount of data. The ECG image from ECG signal is processed by some image processing techniques. To optimize the identification and categorization process, this research presents a hybrid deep learning-based technique. This paper contributes in two ways. Automating noise reduction and extraction of features, 1D ECG data are first converted into 2D pictures. Then, based on experimental evidence, a hybrid model called CNNLSTM is presented, which combines CNN and LSTM models. We conducted a comprehensive research using the broadly used MIT_BIH arrhythmia dataset to assess the efficacy of the proposed CNN-LSTM technique. The results reveal that the proposed method has a 99.10 percent accuracy rate. Furthermore, the proposed model has an average sensitivity of 98.35 percent and a specificity of 98.38 percent. These outcomes are superior to those produced using other procedures, and they will significantly reduce the amount of involvement necessary by physicians.

Indexed as

Deep LearningAlgorithmsArrhythmias, CardiacDatabases, FactualDiagnostic ImagingElectrocardiographyHeart RateHumansNeural Networks, ComputerSignal Processing, Computer-Assisted

Identifiers

PMID35832849
PMCPMC9273451
OpenAlexW4283814016

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.