Evidence map›Paper›PMID 35831734›Full record

ArticleMolecular imaging and biology2023

Three-Dimensional Near-Infrared Specimen Mapping Can Identify the Distance from the Tumor to the Surgical Margin During Resection of Pulmonary Ground Glass Opacities.

Gregory T Kennedy, Feredun S Azari, Elizabeth Bernstein, Charuhas Deshpande, John C Kucharczuk, Edward J Delikatny, Sunil Singhal

Open access · greenAbstract read
In one paragraph

Article in Molecular imaging and biology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Trial
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Gregory T KennedyDepartment of Surgery, University of Pennsylvania School of Medicine, 3400 Spruce Street, 6 White Building, Philadelphia, PA, 19104, USA.
Feredun S AzariDepartment of Surgery, University of Pennsylvania School of Medicine, 3400 Spruce Street, 6 White Building, Philadelphia, PA, 19104, USA.
Elizabeth BernsteinDepartment of Surgery, University of Pennsylvania School of Medicine, 3400 Spruce Street, 6 White Building, Philadelphia, PA, 19104, USA.
Charuhas DeshpandeDepartment of Pathology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA.
John C KucharczukDepartment of Surgery, University of Pennsylvania School of Medicine, 3400 Spruce Street, 6 White Building, Philadelphia, PA, 19104, USA.
Edward J DelikatnyDepartment of Radiology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA.
Sunil SinghalDepartment of Surgery, University of Pennsylvania School of Medicine, 3400 Spruce Street, 6 White Building, Philadelphia, PA, 19104, USA. Sunil.Singhal@pennmedicine.upenn.edu.
University of Pennsylvania · US

Funding

Shared Resource - Core A: Administrative CoreP01CA254859 · NCI · UNIVERSITY OF PENNSYLVANIA · PI Madduri S Srinivasarao · 2022 to 2026
$10.0M
SURGICAL ONCOLOGY RESEARCH TRAINING PROGRAM AT PENNT32CA251063 · NCI · UNIVERSITY OF PENNSYLVANIA · PI Ronald P. Dematteo · 2020 to 2026
$2.6M
Intraoperative Molecular Imaging of Pulmonary Squamous Cell CarcinomaF32CA254210 · NCI · UNIVERSITY OF PENNSYLVANIA · PI KENNEDY, GREGORY T · 2020 to 2021
$143k
NCI NIH HHS F32 CA254210NCI NIH HHS P01 CA254859NCI NIH HHS T32 CA251063
6 · The paper itself

Abstract

backgroundLung cancers can recur locally due to inadequate resection margins. Achieving adequate margin distances is challenging in pulmonary ground glass opacities (GGOs) because they are not easily palpable. To improve margin assessment during resection of GGOs, we propose a novel technique, three-dimensional near-infrared specimen mapping (3D-NSM).

methodsTwenty patients with a cT1 GGO were enrolled and received a fluorescent tracer preoperatively. After resection, specimens underwent 3D-NSM in the operating room. Margins were graded as positive or negative based upon fluorescence at the staple line. Images were analyzed using ImageJ to quantify the distance from the tumor edge to the nearest staple line. This margin distance calculated by 3D-NSM was compared to the margin distance reported on final pathology several days postoperatively.

results3D-NSM identified 20/20 GGOs with no false positive or false negative diagnoses. Mean fluorescence intensity for lesions was 110.92 arbitrary units (A.U.) (IQR: 77.77-122.03 A.U.) compared to 23.68 A.U. (IQR: 19.60-27.06 A.U.) for background lung parenchyma (p < 0.0001). There were 4 tumor-positive or close margins in the study cohort, and all 4 (100%) were identified by 3D-NSM. 3D-NSM margin distances were nearly identical to margin distances reported on final pathology (R

conclusions3D-NSM rapidly localizes GGOs by fluorescence and detects tumor-positive or close surgical margins. 3D-NSM can accurately quantify the resection margin distance as compared to formal pathology, which allows surgeons to rapidly determine whether sublobar resection margin distances are adequate.

Indexed as

Lung NeoplasmsMargins of ExcisionHumansLungGround glass opacitiesIntraoperative molecular imagingThree-dimensional near-infrared specimen mapping

Identifiers

PMID35831734
PMCPMC10237678
OpenAlexW4285394673

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.