ArticleThe Iowa orthopaedic journal2022
Reliability of Multifrequency Bioelectrical Impedance Analysis to Quantify Body Composition in Patients After Musculoskeletal Trauma.
Article in The Iowa orthopaedic journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.
- Body weight and composition endpoints in cancer cachexia clinical trials: Systematic Review 4 of the cachexia endpoints series.Journal of cachexia, sarcopenia and muscle · 2024Pooled it
- The effects of a home-based resistance training programme on body composition and muscle function during weight loss in people living with overweight or obesity: a randomised controlled pilot trial.Nutrition & metabolism · 2025Article
- Assessing limb-specific reliability in body composition: a study on minimal detectable change using bioimpedance analysis.Journal of physical therapy science · 2025Article
- Effects of Exercise Program on Mental, Pulmonary, and Cardiovascular Health of Elderly Men with Acquired Severe Physical Disabilities: A Retrospective Study.Healthcare (Basel, Switzerland) · 2025Article
- Substantial Loss of Skeletal Muscle Mass Occurs After High Energy Trauma.The Iowa orthopaedic journal · 2025Article
- Changes in Muscle Mass and Strength in Adolescents Following High-Intensity Functional Training with Bodyweight Resistance Exercises in Physical Education Lessons.Journal of clinical medicine · 2024Article
- Leucine-enriched amino acid supplementation and exercise to prevent sarcopenia in patients on hemodialysis: a single-arm pilot study.Frontiers in nutrition · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Changes in body composition, especially loss of lean mass, commonly occur in the orthopedic trauma population due to physical inactivity and inadequate nutrition. The purpose of this study was to assess inter-rater and intra-rater reliability of a portable bioelectrical impedance analysis (BIA) device to measure body composition in an orthopedic trauma population after operative fracture fixation. BIA uses a weak electric current to measure impedance (resistance) in the body and uses this to calculate the components of body composition using extensively studied formulas. Methods: Twenty subjects were enrolled, up to 72 hours after operative fixation of musculoskeletal injuries and underwent body composition measurements by two independent raters. One measurement was obtained by each rater at the time of enrollment and again between 1-4 hours after the initial measurement. Reliability was assessed using intraclass correlation coefficients (ICC) and minimum detectable change (MDC) values were calculated from these results. Results: Inter-rater reliability was excellent with ICC values for body fat mass (BFM), lean body mass (LBM), skeletal muscle mass (SMM), dry lean mass (DLM), and percent body fat (PBF) of 0.993, 0.984, 0.984, 0.979, and 0.986 respectively. Intra-rater reliability was also high for BFM, LBM, SMM, DLM, and PBF, at 0.994, 0.989, 0.990, 0.983, 0.987 (rater 1) and 0.994, 0.988, 0.989, 0.985, 0.989 (rater 2). MDC values were calculated to be 4.05 kg for BFM, 4.10 kg for LBM, 2.45 kg for SMM, 1.21 kg for DLM, and 4.83% for PBF. Conclusion: Portable BIA devices are a versatile and attractive option that can reliably be used to assess body composition and changes in lean body mass in the orthopedic trauma population for both research and clinical endeavors.
Indexed as
Identifiers
35821931PMC9210418W4285407932What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.