Evidence map›Paper›PMID 35821562›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

Comparison of rhinomanometric and computational fluid dynamic assessment of nasal resistance with respect to measurement accuracy.

Nora Schmidt, Hans Behrbohm, Leonid Goubergrits, Thomas Hildebrandt, Jan Brüning

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Understanding the mismatch between in-vivo and in-silico rhinomanometry.Medical & biological engineering & computing · 2026
    Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Nora SchmidtDepartment of Otorhinolaryngology and Facial Plastic Surgery, Park-Klinik Weissensee, Schönstraße 80, 13086, Berlin, Germany. nora.schmidt@park-klinik.com.
Hans BehrbohmDepartment of Otorhinolaryngology and Facial Plastic Surgery, Park-Klinik Weissensee, Schönstraße 80, 13086, Berlin, Germany.
Leonid GoubergritsInstitute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Thomas HildebrandtInstitute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.
Jan BrüningInstitute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.ORCID http://orcid.org/0000-0002-0540-7972
Charité - Universitätsmedizin Berlin · DEPark-Klinik Weißensee · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeComputational fluid dynamics (CFD)-based calculation of intranasal airflow became an important method in rhinologic research. Current evidence shows weak to moderate correlation as well as a systematic underprediction of nasal resistance by numerical simulations. In this study, we investigate whether these differences can be explained by measurement uncertainties caused by rhinomanometric devices and procedures. Furthermore, preliminary findings regarding the impact of tissue movements are reported.

methodsA retrospective sample of 17 patients, who reported impaired nasal breathing and for which rhinomanometric (RMM) measurements using two different devices as well as computed tomography scans were available, was investigated in this study. Three patients also exhibited a marked collapse of the nasal valve. Agreement between both rhinomanometric measurements as well as between rhinomanometry and CFD-based calculations was assessed using linear correlation and Bland-Altman analyses. These analyses were performed for the volume flow rates measured at trans-nasal pressure differences of 75 and 150 Pa during inspiration and expiration.

resultsThe correlation between volume flow rates measured using both RMM devices was good (R

conclusionBiases introduced during RMM measurements, by either the chosen device, the operator or other aspects as for example the nasal cycle, are not strong enough to explain the gross differences commonly reported between RMM- and CFD-based measurement of nasal resistance. Additionally, tissue movement during breathing is most likely also no sufficient explanation for these differences.

Indexed as

HydrodynamicsNasal ObstructionHumansNoseRetrospective StudiesRhinomanometryComputational fluid dynamicsComputed tomographyNasal breathingNasal obstructionRhinomanometry

Identifiers

PMID35821562
OpenAlexW4285035163

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.