Evidence map›Paper›PMID 35820663›Full record

ReviewJournal of chemical information and modeling2022

Single-Image Super-Resolution Improvement of X-ray Single-Particle Diffraction Images Using a Convolutional Neural Network.

Atsushi Tokuhisa, Yoshinobu Akinaga, Kei Terayama, Yuji Okamoto, Yasushi Okuno

Open access · hybridAbstract readReview
In one paragraph

Review in Journal of chemical information and modeling, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Atsushi TokuhisaRIKEN Center for Computational Science, 7-1-26, Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047, Japan.ORCID 0000-0002-9584-1819
Yoshinobu AkinagaRIKEN Center for Computational Science, 7-1-26, Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047, Japan.
Kei TerayamaGraduate School of Medical Life Science, Yokohama City University, 1-7-29, Suehiro-cho, Tsurumi-ku, Yokohama, Kanagawa 230-0045, Japan.ORCID 0000-0003-3914-248X
Yuji OkamotoGraduate School of Medicine, Kyoto University, Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507, Japan.
Yasushi OkunoRIKEN Center for Computational Science, 7-1-26, Minatojima-minamimachi, Chuo-ku, Kobe, Hyogo 650-0047, Japan.
Kyoto University · JPRIKEN Center for Computational Science · JPRIKEN Center for Advanced Intelligence Project · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Femtosecond X-ray pulse lasers are promising probes for the elucidation of the multiconformational states of biomolecules because they enable snapshots of single biomolecules to be observed as coherent diffraction images. Multi-image processing using an X-ray free-electron laser has proven to be a successful structural analysis method for viruses. However, the performance of single-particle analysis (SPA) for flexible biomolecules with sizes ≤100 nm remains difficult. Owing to the multiconformational states of biomolecules and noisy character of diffraction images, diffraction image improvement by multi-image processing is often ineffective for such molecules. Herein, a single-image super-resolution (SR) model was constructed using an SR convolutional neural network (SRCNN). Data preparation was performed in silico to consider the actual observation situation with unknown molecular orientations and the fluctuation of molecular structure and incident X-ray intensity. It was demonstrated that the trained SRCNN model improved the single-particle diffraction image quality, corresponding to an observed image with an incident X-ray intensity (approximately three to seven times higher than the original X-ray intensity), while retaining the individuality of the diffraction images. The feasibility of SPA for flexible biomolecules with sizes ≤100 nm was dramatically increased by introducing the SRCNN improvement at the beginning of the various structural analysis schemes.

Indexed as

Image Processing, Computer-AssistedNeural Networks, ComputerLasersX-Ray Diffraction

Identifiers

PMID35820663
PMCPMC9326892
OpenAlexW4285092533

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.