Evidence map›Paper›PMID 35819654›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

3D localization from 2D X-ray projection.

Dagmar Bertsche, Volker Rasche, Wolfgang Rottbauer, Ina Vernikouskaya

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Dagmar BertscheDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.ORCID http://orcid.org/0000-0003-1020-6718
Volker RascheDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.ORCID http://orcid.org/0000-0001-8844-3583
Wolfgang RottbauerDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.
Ina VernikouskayaDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany. ina.vernikouskaya@uni-ulm.de.ORCID http://orcid.org/0000-0002-4187-5685
Universität Ulm · DE

Funding

Bundesministerium für Bildung und Forschung 13GW0372C
6 · The paper itself

Abstract

purposeMost cardiology procedures are guided using X-ray (XR) fluoroscopy. However, the projective nature of the XR fluoroscopy does not allow for true depth perception as required for safe and efficient intervention guidance in structural heart diseases. For improving guidance, different methods have been proposed often being radiation-intensive, time-consuming, or expensive. We propose a simple 3D localization method based on a single monoplane XR projection using a co-registered centerline model.

methodsThe method is based on 3D anatomic surface models and corresponding centerlines generated from preprocedural imaging. After initial co-registration, 2D working points identified in monoplane XR projections are localized in 3D by minimizing the angle between the projection lines of the centerline points and the working points. The accuracy and reliability of the located 3D positions were assessed in 3D using phantom data and in patient data projected to 2D obtained during placement of embolic protection system in interventional procedures.

resultsWith the proposed methods, 2D working points identified in monoplane XR could be successfully located in the 3D phantom and in the patient-specific 3D anatomy. Accuracy in the phantom (3D) resulted in 1.6 mm (± 0.8 mm) on average, and 2.7 mm (± 1.3 mm) on average in the patient data (2D).

conclusionThe use of co-registered centerline models allows reliable and accurate 3D localization of devices from a single monoplane XR projection during placement of the embolic protection system in TAVR. The extension to different vascular interventions and combination with automatic methods for device detection and registration might be promising.

Indexed as

AlgorithmsImaging, Three-DimensionalFluoroscopyHumansPhantoms, ImagingReproducibility of ResultsX-Rays3D localizationCenterline modelCerebral embolic protectionMonoplane projection

Identifiers

PMID35819654
PMCPMC9463320
OpenAlexW4285044503

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.