ArticleJournal of digital imaging2022
Surgical Navigation System for Hypertensive Intracerebral Hemorrhage Based on Mixed Reality.
Article in Journal of digital imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 21 citations in OpenAlex.
- Augmented Reality in Navigated Surgery: A Systematic Review of Clinical Accuracy and System Performance.Mayo Clinic proceedings. Digital health · 2026Review
- From planning to execution: Interactive virtual-reality assisted craniotomy planning in meningioma surgery.Brain & spine · 2026Article
- Prediction of early hematoma enlargement in hypertensive intracerebral hemorrhage using CT and CTA imaging features.Neuroradiology · 2025Article
- Microscopic augmented reality calibration with contactless line-structured light registration for surgical navigation.Medical & biological engineering & computing · 2025Article
- Risk factors and preventive strategies for postoperative cerebral infarction in patients with hypertensive intracerebral hemorrhage.American journal of translational research · 2025Article
- Is Overlain Display a Right Choice for AR Navigation? A Qualitative Study of Head-Mounted Augmented Reality Surgical Navigation on Accuracy for Large-Scale Clinical Deployment.CNS neuroscience & therapeutics · 2025Review
- NextLens-The Next Generation of Surgical Navigation: Proof of Concept of an Augmented Reality System for Surgical Navigation.Journal of neurological surgery. Part B, Skull base · 2024Article
- A Novel Registration Method for a Mixed Reality Navigation System Based on a Laser Crosshair Simulator: A Technical Note.Bioengineering (Basel, Switzerland) · 2023Article
- Surgical Robotics for Intracerebral Hemorrhage Treatment: State of the Art and Future Directions.Annals of biomedical engineering · 2023Review
- State of the Art and Future Prospects of Virtual and Augmented Reality in Veterinary Medicine: A Systematic Review.Animals : an open access journal from MDPI · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hypertensive intracerebral hemorrhage (HICH) is an intracerebral bleeding disease that affects 2.5 per 10,000 people worldwide each year. An effective way to cure this disease is puncture through the dura with a brain puncture drill and tube; the accuracy of the insertion determines the quality of the surgery. In recent decades, surgical navigation systems have been widely used to improve the accuracy of surgery and minimize risks. Augmented reality- and mixed reality-based surgical navigation is a promising new technology for surgical navigation in the clinic, aiming to improve the safety and accuracy of the operation. In this study, we present a novel multimodel mixed reality navigation system for HICH surgery in which medical images and virtual anatomical structures can be aligned intraoperatively with the actual structures of the patient in a head-mounted device and adjusted when the patient moves in real time while under local anesthesia; this approach can help the surgeon intuitively perform intraoperative navigation. A novel registration method is used to register the holographic space and serves as an intraoperative optical tracker, and a method for calibrating the HICH surgical tools is used to track the tools in real time. The results of phantom experiments revealed a mean registration error of 1.03 mm and an average time consumption of 12.9 min. In clinical usage, the registration error was 1.94 mm, and the time consumption was 14.2 min, showing that this system is sufficiently accurate and effective for clinical application.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.