Evidence map›Paper›PMID 35818313›Full record

ArticlePhysiological reports2022

Combined head accelerometry and EEG improves the detection of respiratory-related cortical activity during inspiratory loading in healthy participants.

Anna L Hudson, Nicolas Wattiez, Xavier Navarro-Sune, Mario Chavez, Thomas Similowski

Open access · goldAbstract read
In one paragraph

Article in Physiological reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Anna L HudsonCollege of Medicine and Public Health, Flinders University, Adelaide, Australia.ORCID 0000-0002-0192-776X
Nicolas WattiezSorbonne Université, INSERM UMRS1158 Neurophysiologie Respiratoire Expérimentale et Clinique, Paris, France.
Xavier Navarro-SuneSorbonne Université, INSERM UMR 1127, CNRS UMR 7225, Institut du Cerveau et de la Moelle Épinière, Paris, France.
Mario ChavezSorbonne Université, INSERM UMR 1127, CNRS UMR 7225, Institut du Cerveau et de la Moelle Épinière, Paris, France.
Thomas SimilowskiSorbonne Université, INSERM UMRS1158 Neurophysiologie Respiratoire Expérimentale et Clinique, Paris, France.
Inserm · FRCentre National de la Recherche Scientifique · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mechanical ventilation is a highly utilized life-saving tool, particularly in the current era. The use of EEG in a brain-ventilator interface (BVI) to detect respiratory discomfort (due to sub-optimal ventilator settings) would improve treatment in mechanically ventilated patients. This concept has been realized via development of an EEG covariance-based classifier that detects respiratory-related cortical activity associated with respiratory discomfort. The aim of this study was to determine if head movement, detected by an accelerometer, can detect and/or improve the detection of respiratory-related cortical activity compared to EEG alone. In 25 healthy participants, EEG and acceleration of the head were recorded during loaded and quiet breathing in the seated and lying postures. Detection of respiratory-related cortical activity using an EEG covariance-based classifier was improved by inclusion of data from an Accelerometer-based classifier, i.e. classifier 'Fusion'. In addition, 'smoothed' data over 50s, rather than one 5 s window of EEG/Accelerometer signals, improved detection. Waveform averages of EEG and head acceleration showed the incidence of pre-inspiratory potentials did not differ between loaded and quiet breathing, but head movement was greater in loaded breathing. This study confirms that compared to event-related analysis with >5 min of signal acquisition, an EEG-based classifier is a clinically valuable tool with rapid processing, detection times, and accuracy. Data smoothing would introduce a small delay (<1 min) but improves detection results. As head acceleration improved detection compared to EEG alone, the number of EEG signals required to detect respiratory discomfort with future BVIs could be reduced if head acceleration is included.

Indexed as

ElectroencephalographyRespirationAccelerometryHealthy VolunteersHumansRespiratory RateBereitschaftspotentialbrain computer interfaceclassifier fusioncovariance classifierelectroencephalography

Identifiers

PMID35818313
PMCPMC9273870
OpenAlexW4285045864

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.