Accuracy measurement of different marker based motion analysis systems for biomechanical applications: A round robin study.

Stefan Schroeder, Sebastian Jaeger, Jonas Schwer, Andreas Martin Seitz, Isabell Hamann, Michael Werner, Christoph Thorwaechter, Inês Santos, Toni Wendler, Dennis Nebel and 1 more

Abstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Investigation of instrumentation lengthening in the thoracolumbar junction of the spine - an in vitro Biomechanical study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  5. K-wires as a valid alternative to dual and single headless cannulated compression screw fixation of chauffeur fractures: a biomechanical comparison.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Article
  6. Impact of caudal segment bone fusion on rod load at the cranial segment in a two-level spinal interbody fusion construct- a biomechanical study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Collateral ligament strain is linearly related to coronal lower limb alignment: A biomechanical study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025
    Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Stefan SchroederLaboratory of Biomechanics and Implant Research, Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany.
Sebastian JaegerLaboratory of Biomechanics and Implant Research, Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany.
Jonas SchwerInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Ulm, Germany.
Andreas Martin SeitzInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Ulm, Germany.
Isabell HamannFraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany.
Michael WernerFraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany.
Christoph ThorwaechterDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
Inês SantosDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
Toni WendlerZESBO-Center for Research on Musculoskeletal Systems, Leipzig University, Leipzig, Germany.
Dennis NebelLaboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Hannover, Germany.
Bastian WelkeLaboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Hannover, Germany.ORCID 0000-0003-2526-8129

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionMultiple camera systems are widely used for 3D-motion analysis. Due to increasing accuracies these camera systems gained interest in biomechanical research areas, where high precision measurements are desirable. In the current study different measurement systems were compared regarding their measurement accuracy. MATERIALS AND

methodsTranslational and rotational accuracy measurements as well as the zero offset measurements of seven different measurement systems were performed using two reference devices and two different evaluation algorithms. All measurements were performed in the same room with constant temperature at the same laboratory. Equal positions were measured with the systems according to a standardized protocol. Measurement errors were determined and compared.

resultsThe highest measurement errors were seen for a measurement system using active ultrasonic markers, followed by another active marker measurement system (infrared) having measurement errors up to several hundred micrometers. The highest accuracies were achieved by three stereo camera systems, using passive 2D marker points having errors typically below 20 μm.

conclusionsThis study can help to better assess the results obtained with different measurement systems. With the focus on the measurement accuracy, only one aspect in the selection of a system was considered. Depending on the requirements of the user, other factors like measurement frequency, the maximum analyzable volume, the marker type or the costs are important factors as well.

Indexed as

AlgorithmsBiomechanical PhenomenaMotion

Identifiers

PMID35816503
PMCPMC9273086

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.