Evidence map›Paper›PMID 35812804›Full record

ArticleMicrosystems & nanoengineering2022

A force measurement platform for a vitreoretinal surgical simulator using an artificial eye module integrated with a quartz crystal resonator.

Yuta Taniguchi, Hirotaka Sugiura, Toshiro Yamanaka, Shiro Watanabe, Seiji Omata, Kanako Harada, Mamoru Mitsuishi, Tomoyasu Shiraya, Koichiro Sugimoto, Takashi Ueta and 5 more

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Evaluation of (Shared) Autonomy in Robot-Assisted Vitreoretinal Surgery Using a Surgical Model.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Yuta TaniguchiDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 Japan.
Hirotaka SugiuraDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 Japan.
Toshiro YamanakaDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 Japan.
Shiro WatanabeDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 Japan.
Seiji OmataFaculty of Advanced Science and Technology, Kumamoto University, 2-39-1 Kurokami, Chuo-ku, Kumamoto-shi, Kumamoto, 860-8555 Japan.
Kanako HaradaCenter for Disease Biology and Integrative Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 Japan.
Mamoru MitsuishiDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 Japan.
Tomoyasu ShirayaDepartment of Ophthalmology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan.
Koichiro SugimotoDepartment of Ophthalmology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan.
Takashi UetaDepartment of Ophthalmology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan.
Kiyohito TotsukaDepartment of Ophthalmology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan.
Fumiyuki ArakiDepartment of Ophthalmology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan.
Muneyuki TakaoDepartment of Ophthalmology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan.
Makoto AiharaDepartment of Ophthalmology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan.
Fumihito AraiDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To provide quantitative feedback on surgical progress to ophthalmologists practicing inner limiting membrane (ILM) peeling, we developed an artificial eye module comprising a quartz crystal resonator (QCR) force sensor and a strain body that serves as a uniform force transmitter beneath a retinal model. Although a sufficiently large initial force must be loaded onto the QCR force sensor assembly to achieve stable contact with the strain body, the highly sensitive and wide dynamic-range property of this sensor enables the eye module to detect the slight forceps contact force. A parallel-plate strain body is used to achieve a uniform force sensitivity over the 4-mm-diameter ILM peeling region. Combining these two components allowed for a measurable force range of 0.22 mN to 29.6 N with a sensitivity error within -11.3 to 4.2% over the ILM peeling area. Using this eye module, we measured the applied force during a simulation involving artificial ILM peeling by an untrained individual and compensated for the long-term drift of the obtained force data using a newly developed algorithm. The compensated force data clearly captured the characteristics of several types of motion sequences observed from video recordings of the eye bottom using an ophthalmological microscope. As a result, we succeeded in extracting feature values that can be potentially related to trainee skill level, such as the mean and standard deviation of the pushing and peeling forces, corresponding, in the case of an untrained operator, to 122.6 ± 95.2 and 20.4 ± 13.2 mN, respectively.

Indexed as

EngineeringSensors

Identifiers

PMID35812804
PMCPMC9256705

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.