Evidence map›Paper›PMID 35812224›Full record

ArticleFrontiers in neuroscience2022

Evaluating the Safety of Simultaneous Intracranial Electroencephalography and Functional Magnetic Resonance Imaging Acquisition Using a 3 Tesla Magnetic Resonance Imaging Scanner.

Yuya Fujita, Hui Ming Khoo, Miki Hirayama, Masaaki Kawahara, Yoshihiro Koyama, Hiroyuki Tarewaki, Atsuko Arisawa, Takufumi Yanagisawa, Naoki Tani, Satoru Oshino and 2 more

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 2 countries.

Yuya FujitaDepartment of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan.
Hui Ming KhooDepartment of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan.
Miki HirayamaDepartment of Radiology, Osaka University Hospital, Suita, Japan.
Masaaki KawaharaDepartment of Radiology, Osaka University Hospital, Suita, Japan.
Yoshihiro KoyamaDepartment of Radiology, Osaka University Hospital, Suita, Japan.
Hiroyuki TarewakiDepartment of Radiology, Osaka University Hospital, Suita, Japan.
Atsuko ArisawaDepartment of Radiology, Osaka University Graduate School of Medicine, Suita, Japan.
Takufumi YanagisawaDepartment of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan.
Naoki TaniDepartment of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan.
Satoru OshinoDepartment of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan.
Louis LemieuxDepartment of Clinical and Experimental Epilepsy, UCL Queen Square Institute of Neurology, London, United Kingdom.
Haruhiko KishimaDepartment of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan.
Osaka University · JPOsaka University Hospital · JPNational Hospital for Neurology and Neurosurgery · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The unsurpassed sensitivity of intracranial electroencephalography (icEEG) and the growing interest in understanding human brain networks and ongoing activities in health and disease have make the simultaneous icEEG and functional magnetic resonance imaging acquisition (icEEG-fMRI) an attractive investigation tool. However, safety remains a crucial consideration, particularly due to the impact of the specific characteristics of icEEG and MRI technologies that were safe when used separately but may risk health when combined. Using a clinical 3-T scanner with body transmit and head-receive coils, we assessed the safety and feasibility of our icEEG-fMRI protocol. Methods: Using platinum and platinum-iridium grid and depth electrodes implanted in a custom-made acrylic-gel phantom, we assessed safety by focusing on three factors. First, we measured radio frequency (RF)-induced heating of the electrodes during fast spin echo (FSE, as a control) and the three sequences in our icEEG-fMRI protocol. Heating was evaluated with electrodes placed orthogonal or parallel to the static magnetic field. Using the configuration with the greatest heating observed, we then measured the total heating induced in our protocol, which is a continuous 70-min icEEG-fMRI session comprising localizer, echo-planar imaging (EPI), and magnetization-prepared rapid gradient-echo sequences. Second, we measured the gradient switching-induced voltage using configurations mimicking electrode implantation in the frontal and temporal lobes. Third, we assessed the gradient switching-induced electrode movement by direct visual detection and image analyses. Results: On average, RF-induced local heating on the icEEG electrode contacts tested were greater in the orthogonal than parallel configuration, with a maximum increase of 0.2°C during EPI and 1.9°C during FSE. The total local heating was below the 1°C safety limit across all contacts tested during the 70-min icEEG-fMRI session. The induced voltage was within the 100-mV safety limit regardless of the configuration. No gradient switching-induced electrode displacement was observed. Conclusion: We provide evidence that the additional health risks associated with heating, neuronal stimulation, or device movement are low when acquiring fMRI at 3 T in the presence of clinical icEEG electrodes under the conditions reported in this study. High specific absorption ratio sequences such as FSE should be avoided to prevent potential inadvertent tissue heating.

Indexed as

3 tesladepth electrodeepilepsyfMRIMRIsafetysimultaneous intracranial EEG-fMRIsubdural electrode

Identifiers

PMID35812224
PMCPMC9259878
OpenAlexW4283316897

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.