Evidence map›Paper›PMID 35809105›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023

Medial congruent polyethylene design show different tibiofemoral kinematics and enhanced congruency compared to a standard symmetrical cruciate retaining design for total knee arthroplasty-an in vivo randomized controlled study of gait using dynamic radiostereometry.

Emil Toft Petersen, Søren Rytter, Daan Koppens, Jesper Dalsgaard, Torben Bæk Hansen, Michael Skipper Andersen, Maiken Stilling

2 registry-linked trialsAbstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05651009 naactive not recruitingnot on this map

Comparison of the in Vivo Stability of 2 Cementless TKA Designs Using CT Micromotion Analysis - A Randomized Controlled Trial

TypeinterventionalSponsorHelse Møre og Romsdal HFRan2022 to 2033Enrolled50ConditionsKnee OsteoarthritisArmsTKA
NCT06507046 narecruitingnot on this mapstarted 2024, after this paper: background citation

Robotic Assisted Surgery Comparing Personalized Alignment Versus Mechanical Alignment of Total Knee Arthroplasty - A Randomized Controlled Trial

TypeinterventionalSponsorHelse Møre og Romsdal HFRan2024 to 2035Enrolled152ConditionsKnee OsteoarthritisArmsTotal knee replacement
3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. The Effect of the Design of Polyethylene Inserts in Total Knee Arthroplasty on Patient Reported Outcomes.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2025
    Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Emil Toft PetersenUniversity Clinic for Hand, Hip and Knee Surgery, Holstebro Central Hospital, Holstebro, Denmark. emiltp@clin.au.dk.ORCID http://orcid.org/0000-0003-1697-8778
Søren RytterDepartment of Clinical Medicine, Aarhus University, Aarhus N, Denmark.
Daan KoppensUniversity Clinic for Hand, Hip and Knee Surgery, Holstebro Central Hospital, Holstebro, Denmark.
Jesper DalsgaardUniversity Clinic for Hand, Hip and Knee Surgery, Holstebro Central Hospital, Holstebro, Denmark.
Torben Bæk HansenUniversity Clinic for Hand, Hip and Knee Surgery, Holstebro Central Hospital, Holstebro, Denmark.
Michael Skipper AndersenDepartment of Materials and Production, Aalborg University, Aalborg, Denmark.
Maiken StillingDepartment of Clinical Medicine, Aarhus University, Aarhus N, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeNew total knee arthroplasty implant designs attempt to normalize kinematics patterns that may improve functional performance and patient satisfaction. It was hypothesized that a more medial congruent (MC) anatomic bearing design (1) influences the tibiofemoral kinematics and (2) enhances articular congruency compared to a standard symmetrical cruciate retaining (CR) bearing design.

methodsIn this double-blinded randomized study, 66 patients with knee osteoarthritis were randomly included in two groups: MC (n = 31) and CR (n = 33). Clinical characteristics such as knee ligament lesions and knee osteoarthritis scores were graded on preoperative magnetic resonance imaging and radiography. At the 1-year follow-up, dynamic radiostereometric analysis was used to assess tibiofemoral joint kinematics and articulation congruency. Patient-reported outcome measures, Oxford Knee Score, the Forgotten Joint Score, and the Knee Osteoarthritis Outcome Score, were assessed preoperatively and at the 1-year follow-up.

resultsCompared to the CR bearing, the MC bearing displayed an offset with approximately 3 mm greater anterior tibial drawer (p < 0.001) during the entire motion, and up to approximately 3.5 degrees more tibial external rotation (p = 0.004) from mid-swing to the end of the gait cycle at the 1-year follow-up. Furthermore, the congruency area in the joint articulation was larger during approximately 80% of the gait cycle for the MC bearing compared to the CR. The patient-reported outcome measures improved (p < 0.001), but there were no differences between groups. In addition, there were no differences in clinical characteristics and there were no knee revisions or recognized deep infections during follow-up.

conclusionThe study demonstrates that the MC-bearing design changes tibiofemoral kinematics and increases the area of congruency towards more native knee kinematics than the CR bearing. In perspective this may contribute to a more stabilized knee motion, restoring the patient's confidence in knee function during daily activities.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeAnterior Cruciate LigamentBiomechanical PhenomenaGaitHumansKnee JointPolyethyleneRadiostereometric AnalysisRange of Motion, ArticularPolyethyleneDouble-blinded randomized controlledGaitJoint congruencyJoint kinematicsMedial congruentRadiostereometric analysisTotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials