Evidence map›Paper›PMID 35808526›Full record

ArticleSensors (Basel, Switzerland)2022

Accuracy of a New Pulse Oximetry in Detection of Arterial Oxygen Saturation and Heart Rate Measurements: The SOMBRERO Study.

Stefano Marinari, Pasqualina Volpe, Marzia Simoni, Matteo Aventaggiato, Fernando De Benedetto, Stefano Nardini, Claudio M Sanguinetti, Paolo Palange

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Accuracy of Rhythm Diagnostic Systems' MultiSenseSensors (Basel, Switzerland) · 2024
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Stefano MarinariRespiratory Disease Unit, G. Mazzini Hospital, 64100 Teramo, Italy.
Pasqualina VolpePresidio PneumoTisiologico Territoriale ASL 02, 66100 Chieti, Italy.
Marzia SimoniCNR Institute of Clinical Physiology, 56124 Pisa, Italy.
Matteo AventaggiatoIndependent Researcher, 73100 Lecce, Italy.
Fernando De BenedettoFISAR Foundation (Fondazione Salute Ambiente e Respiro), 66100 Chieti, Italy.
Stefano NardiniItalian Multidisciplinary Respiratory Society, 20127 Milan, Italy.
Claudio M SanguinettiEditorial Activities, Italian Multidisciplinary Respiratory Society, 20127 Milan, Italy.
Paolo PalangeDepartment of Public Health and Infectious Diseases, Division of Respiratory Diseases, Umberto I Hospital, Sapienza University, 00161 Rome, Italy.

Funding

Life Meters Srl 01M2020-CH.LMD
6 · The paper itself

Abstract

Early diagnosis and continuous monitoring of respiratory failure (RF) in the course of the most prevalent chronic cardio-vascular (CVD) and respiratory diseases (CRD) are a clinical, unresolved problem because wearable, non-invasive, and user-friendly medical devices, which could grant reliable measures of the oxygen saturation (SpO2) and heart rate (HR) in real-life during daily activities are still lacking. In this study, we investigated the agreement between a new medical wrist-worn device (BrOxy M) and a reference, medical pulseoximeter (Nellcor PM 1000N). Twelve healthy volunteers (aged 20−51 years, 84% males, 33% with black skin, obtaining, during the controlled hypoxia test, the simultaneous registration of 219 data pairs, homogeneously deployed in the levels of Sat.O2 97%, 92%, 87%, 82% [ISO 80601-2-61:2017 standard (paragraph EE.3)]) were included. The paired T test 0 and the Bland-Altman plot were performed to assess bias and accuracy. SpO2 and HR readings by the two devices resulted significantly correlated (r = 0.91 and 0.96, p < 0.001, respectively). Analyses excluded the presence of proportional bias. For SpO2, the mean bias was −0.18% and the accuracy (ARMS) was 2.7%. For HR the mean bias was 0.25 bpm and the ARMS3.7 bpm. The sensitivity to detect SpO2 ≤ 94% was 94.4%. The agreement between BrOxy M and the reference pulse oximeter was “substantial” (for SpO2 cut-off 94% and 90%, k = 0.79 and k = 0.80, respectively). We conclude that BrOxy M demonstrated accuracy, reliability and consistency in measuring SpO2 and HR, being fully comparable with a reference medical pulseoxymeter, with no adverse effects. As a wearable device, Broxy M can measure continually SpO2 and HR in everyday life, helping in detecting and following up CVD and CRD subjects.

Indexed as

Cardiovascular DiseasesOxygen SaturationFemaleHeart RateHumansMaleOximetryOxygenReproducibility of ResultsOxygenchronic cardiac diseaseschronic respiratory diseasesheart ratepulse oxygen saturationreflective pulseoximeterSpO2wrist-watch pulsoximeter

Identifiers

PMID35808526
PMCPMC9269825

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.