Evidence map›Paper›PMID 35808479›Full record

ArticleSensors (Basel, Switzerland)2022

Microsoft Azure Kinect Calibration for Three-Dimensional Dense Point Clouds and Reliable Skeletons.

Laura Romeo, Roberto Marani, Anna Gina Perri, Tiziana D'Orazio

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Simulation of Human Movement in Zero Gravity.Sensors (Basel, Switzerland) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Laura RomeoNational Research Council of Italy (CNR), Institute of Intelligent Industrial Technologies and Systems for Advanced Manufacturing (STIIMA), Via Amendola 122 D/O, 70126 Bari, Italy.ORCID 0000-0001-8138-893X
Roberto MaraniNational Research Council of Italy (CNR), Institute of Intelligent Industrial Technologies and Systems for Advanced Manufacturing (STIIMA), Via Amendola 122 D/O, 70126 Bari, Italy.ORCID 0000-0002-5599-903X
Anna Gina PerriDepartment of Electrical and Information Engineering (DEI), Polytechnic University of Bari, Via Orabona 4, 70126 Bari, Italy.ORCID 0000-0003-4949-987X
Tiziana D'OrazioNational Research Council of Italy (CNR), Institute of Intelligent Industrial Technologies and Systems for Advanced Manufacturing (STIIMA), Via Amendola 122 D/O, 70126 Bari, Italy.ORCID 0000-0003-1473-7110

Funding

Italian Ministry of Economic Development LAMPO "Leonardo Automated Manufacturing Processes for cOmposites" CDS000750
6 · The paper itself

Abstract

Nowadays, the need for reliable and low-cost multi-camera systems is increasing for many potential applications, such as localization and mapping, human activity recognition, hand and gesture analysis, and object detection and localization. However, a precise camera calibration approach is mandatory for enabling further applications that require high precision. This paper analyzes the available two-camera calibration approaches to propose a guideline for calibrating multiple Azure Kinect RGB-D sensors to achieve the best alignment of point clouds in both color and infrared resolutions, and skeletal joints returned by the Microsoft Azure Body Tracking library. Different calibration methodologies using 2D and 3D approaches, all exploiting the functionalities within the Azure Kinect devices, are presented. Experiments demonstrate that the best results are returned by applying 3D calibration procedures, which give an average distance between all couples of corresponding points of point clouds in color or an infrared resolution of 21.426 mm and 9.872 mm for a static experiment and of 20.868 mm and 7.429 mm while framing a dynamic scene. At the same time, the best results in body joint alignment are achieved by three-dimensional procedures on images captured by the infrared sensors, resulting in an average error of 35.410 mm.

Indexed as

GesturesSkeletonCalibrationHumansAzure Kinectcalibrationcomputer visionpoint cloudskeleton

Identifiers

PMID35808479
PMCPMC9269787

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.