Evidence map›Paper›PMID 35808413›Full record

ArticleSensors (Basel, Switzerland)2022

Preliminary Evaluation of a Blast Sprayer Controlled by Pulse-Width-Modulated Nozzles.

Enrique Ortí, Andrés Cuenca, Montano Pérez, Antonio Torregrosa, Coral Ortiz, Francisco Rovira-Más

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Enrique OrtíDepartamento de Ingeniería Rural y Agroalimentaria, Universitat Politècnica de València, 46022 Valencia, Spain.
Andrés CuencaDepartamento de Ingeniería Rural y Agroalimentaria, Universitat Politècnica de València, 46022 Valencia, Spain.
Montano PérezDepartamento de Ingeniería Rural y Agroalimentaria, Universitat Politècnica de València, 46022 Valencia, Spain.
Antonio TorregrosaDepartamento de Ingeniería Rural y Agroalimentaria, Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0003-1122-5187
Coral OrtizDepartamento de Ingeniería Rural y Agroalimentaria, Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0002-2744-6964
Francisco Rovira-MásDepartamento de Ingeniería Rural y Agroalimentaria, Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0002-2589-9281

Funding

Spanish Ministry of Science and Innovation (Ministerio de Ciencia e Innovación (Gobierno de España)) PID2019-104289RB 2020-2023
6 · The paper itself

Abstract

Precision spraying relies on the response of the spraying equipment to the features of the targeted canopy. PWM technology manages the flow rate using a set of electronically actuated solenoid valves to regulate flow rate at the nozzle level. Previous studies have found that PWM systems may deliver incorrect flow rates. The objective of the present study was to characterize the performance of a commercial blast sprayer modified with pulse-width-modulated nozzles under laboratory conditions, as a preliminary step before its further field validation. Four different duty cycles (25 percent, 50 percent, 75 percent and 100 percent) and four different pressures (400 kPa, 500 kPa, 600 kPa and 700 kPa) were combined to experimentally measure the flow rate of each nozzle. Results showed that the PWM nozzles mounted in the commercial blast sprayer, under static conditions, were capable of modulating flow rate according to the duty cycle. However, the reduction of flow rates for the tested duty cycles according to pressure was lower than the percentage expected. A good linear relation was found between the pressure registered by the control system feedback sensor and the pressure measured by a reference conventional manometer located after the pump. High-speed video recordings confirmed the accurate opening and closing of the nozzles according to the duty cycle; however, substantial pressure variations were found at nozzle level. Further research to establish the general suitability of PWM systems for regulating nozzle flow rates in blast sprayers without modifying the system pressure still remains to be addressed.

Indexed as

blast sprayerprecision sprayingPWM nozzles

Identifiers

PMID35808413
PMCPMC9269797

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.