Evidence map›Paper›PMID 35808340›Full record

ArticleSensors (Basel, Switzerland)2022

Noise Filtering Method of Digital Holographic Microscopy for Obtaining an Accurate Three-Dimensional Profile of Object Using a Windowed Sideband Array (WiSA).

Hyun-Woo Kim, Myungjin Cho, Min-Chul Lee

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Hyun-Woo KimDepartment of Computer Science and Networks, Kyushu Institute of Technology, 680-4 Kawazu, Fukuoka 820-8502, Japan.ORCID 0000-0003-1381-6116
Myungjin ChoSchool of ICT, Robotics, and Mechanical Engineering, Research Center for Hyper-Connected Convergence Technology, IITC, Hankyong National University, 327 Chungang-ro, Anseong 17579, Korea.ORCID 0000-0003-2896-770X
Min-Chul LeeDepartment of Computer Science and Networks, Kyushu Institute of Technology, 680-4 Kawazu, Fukuoka 820-8502, Japan.ORCID 0000-0001-8469-0288
Kyushu Institute of Technology · JPHankyong National University · KR

Funding

Japan Society for the Promotion of Science JPJSBP 120228811National Research Foundation of Korea NRF-2022K2A9A2A08000152, FY2022
6 · The paper itself

Abstract

In the image processing method of digital holographic microscopy (DHM), we can obtain a phase information of an object by windowing a sideband in Fourier domain and taking inverse Fourier transform. In this method, it is necessary to window a wide sideband to obtain detailed information on the object. However, since the information of the DC spectrum is widely distributed over the entire range from the center of Fourier domain, the window sideband includes not only phase information but also DC information. For this reason, research on acquiring only the phase information of an object without noise in digital holography is a challenging issue for many researchers. Therefore, in this paper, we propose the use of a windowed sideband array (WiSA) as an image processing method to obtain an accurate three-dimensional (3D) profile of an object without noise in DHM. The proposed method does not affect the neighbor pixels of the filtered pixel but removes noise while maintaining the detail of the object. Thus, a more accurate 3D profile can be obtained compared with the conventional filter. In this paper, we create an ideal comparison target i.e., microspheres for comparison, and verify the effect of the filter through additional experiments using red blood cells.

Indexed as

HolographyMicroscopyFourier AnalysisHumansSignal-To-Noise Ratiodigital holographic microscopynoise reductionthree-dimensional imaging

Identifiers

PMID35808340
PMCPMC9269282
OpenAlexW4283654085

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.