Evidence map›Paper›PMID 35808298›Full record

ArticleSensors (Basel, Switzerland)2022

Energy-Accuracy Aware Finger Gesture Recognition for Wearable IoT Devices.

Woosoon Jung, Hyung Gyu Lee

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Wearable Sensors Applied in Movement Analysis.Sensors (Basel, Switzerland) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Woosoon JungDepartment of Computer and Information Engineering, Daegu University, Gyeongsan-si 38453, Korea.ORCID 0000-0001-7382-3049
Hyung Gyu LeeDepartment of Software, Duksung Women's University, Seoul 01369, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable Internet of Things (IoT) devices can be used efficiently for gesture recognition applications. The nature of these applications requires high recognition accuracy with low energy consumption, which is not easy to solve at the same time. In this paper, we design a finger gesture recognition system using a wearable IoT device. The proposed recognition system uses a light-weight multi-layer perceptron (MLP) classifier which can be implemented even on a low-end micro controller unit (MCU), with a 2-axes flex sensor. To achieve high recognition accuracy with low energy consumption, we first design a framework for the finger gesture recognition system including its components, followed by system-level performance and energy models. Then, we analyze system-level accuracy and energy optimization issues, and explore the numerous design choices to finally achieve energy-accuracy aware finger gesture recognition, targeting four commonly used low-end MCUs. Our extensive simulation and measurements using prototypes demonstrate that the proposed design achieves up to 95.5% recognition accuracy with energy consumption under 2.74 mJ per gesture on a low-end embedded wearable IoT device. We also provide the Pareto-optimal designs among a total of 159 design choices to achieve energy-accuracy aware design points under given energy or accuracy constraints.

Indexed as

FingersGesturesPattern Recognition, AutomatedHumansInternet of ThingsReproducibility of ResultsWearable Electronic Devicesflex sensorgesture recognitionMLPmodel searchneural network

Identifiers

PMID35808298
PMCPMC9268903

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.