ArticleSensors (Basel, Switzerland)2022
Indoor Localization Method of Personnel Movement Based on Non-Contact Electrostatic Potential Measurements.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The indoor localization of people is the key to realizing "smart city" applications, such as smart homes, elderly care, and an energy-saving grid. The localization method based on electrostatic information is a passive label-free localization technique with a better balance of localization accuracy, system power consumption, privacy protection, and environmental friendliness. However, the physical information of each actual application scenario is different, resulting in the transfer function from the human electrostatic potential to the sensor signal not being unique, thus limiting the generality of this method. Therefore, this study proposed an indoor localization method based on on-site measured electrostatic signals and symbolic regression machine learning algorithms. A remote, non-contact human electrostatic potential sensor was designed and implemented, and a prototype test system was built. Indoor localization of moving people was achieved in a 5 m × 5 m space with an 80% positioning accuracy and a median error absolute value range of 0.4-0.6 m. This method achieved on-site calibration without requiring physical information about the actual scene. It has the advantages of low computational complexity and only a small amount of training data is required.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.