Evidence map›Paper›PMID 35808178›Full record

ArticleSensors (Basel, Switzerland)2022

Development of Joint Activity Angle Measurement and Cloud Data Storage System.

Chiu-Ching Tuan, Yi-Chao Wu, Wen-Ling Yeh, Chun-Chieh Wang, Chi-Heng Lu, Shao-Wei Wang, Jack Yang, Tsair-Fwu Lee, Hsuan-Kai Kao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Chiu-Ching TuanDepartment of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
Yi-Chao WuInterdisciplinary Program of Green and Information Technology, National Taitung University, Taitung 95092, Taiwan.
Wen-Ling YehDepartment of Orthopedics, Lotung Poh-Ai Hospital, Yilan 26546, Taiwan.ORCID 0000-0002-2858-5552
Chun-Chieh WangDepartment of Radiation Oncology, Chang Gung Memorial Hospital at Linkou, Taoyuan 33305, Taiwan.
Chi-Heng LuDepartment of Radiation Oncology, Chang Gung Memorial Hospital at Linkou, Taoyuan 33305, Taiwan.ORCID 0000-0001-9348-0899
Shao-Wei WangDepartment of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
Jack YangDepartment of Radiation Oncology, RWJ Medical School, Monmouth Medical Center, Long Branch, NJ 07740, USA.
Tsair-Fwu LeeDepartment of Electronics Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 80708, Taiwan.ORCID 0000-0002-3112-3594
Hsuan-Kai KaoBone and Joint Research Center, Chang Gung Memorial Hospital, Linkou 33305, Taiwan.

Funding

Chang Gung Memorial Hospital CGMH-CORPG3K0111National Taipei University NTUT-CGMH-109-02
6 · The paper itself

Abstract

In this study, we developed a range of motion sensing system (ROMSS) to simulate the function of the elbow joint, with errors less than 0.76 degrees and 0.87 degrees in static and dynamic verification by the swinging and angle recognition modules, respectively. In the simulation process, the ɣ correlation coefficient of the Pearson difference between the ROMSS and the universal goniometer was 0.90, the standard deviations of the general goniometer measurements were between ±2 degrees and ±2.6 degrees, and the standard deviations between the ROMSS measurements were between ±0.5 degrees and ±1.6 degrees. With the ROMSS, a cloud database was also established; the data measured by the sensor could be uploaded to the cloud database in real-time to provide timely patient information for healthcare professionals. We also developed a mobile app for smartphones to enable patients and healthcare providers to easily trace the data in real-time. Historical data sets with joint activity angles could be retrieved to observe the progress or effectiveness of disease recovery so the quality of care could be properly assessed and maintained.

Indexed as

Elbow JointArthrometry, ArticularHumansInformation Storage and RetrievalRange of Motion, ArticularReproducibility of ResultsSmartphonecloud databaseelbow range of motion (ROM)extremities rehabilitationgoniometerKalman filterweighted moving average filter (WMAF)

Identifiers

PMID35808178
PMCPMC9269277

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.