ArticleJournal of clinical medicine2022
Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study.
Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- CBCT Assessment for Dental Implant Surgery at the Maxilla: A Clinical Update.Diagnostics (Basel, Switzerland) · 2026Review
- Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study.BMC oral health · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of this study was to assess the impact of dimensional distortion and its changes with modification of exposure setting parameters on the measurements of peri-implant bone margin. Ten titanium dental implants (InKone Primo, Global D, Paris, France) were placed in two prepared bovine ribs. Two bone models and an implant-with-transfer model were scanned with 3shape E4 (3shape, Copenhagen, Denmark) laboratory scanner. Cone beam computed tomography (CBCT) images of two bone models were taken with different values of voltage (60, 70, 80, 90 kV), tube current (4, 10 mA) and voxel size (200, 300 µm). All the data were superimposed using planning software, and the measurements of buccal bone thickness in two selected regions were performed both using CBCT and scan cross-sections. The mean squared error (MSE) being the squared differences between measurements was used in the accuracy assessment of the CBCT device. A one-way ANOVA revealed significant differences between voltage and MSE (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.