Evidence map›Paper›PMID 35806942›Full record

ArticleJournal of clinical medicine2022

Forced Oscillation Measurements in Patients with Idiopathic Interstitial Pneumonia Subjected to Pulmonary Rehabilitation.

Sabina Kostorz-Nosal, Dariusz Jastrzębski, Piotr Kubicki, Dagmara Galle, Alicja Gałeczka-Turkiewicz, Beata Toczylowska, Dariusz Ziora

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Sabina Kostorz-NosalDepartment of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-032 Katowice, Poland.ORCID 0000-0002-4844-0609
Dariusz JastrzębskiDepartment of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-032 Katowice, Poland.
Piotr KubickiDepartment of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-032 Katowice, Poland.
Dagmara GalleDepartment of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-032 Katowice, Poland.ORCID 0000-0003-3313-8084
Alicja Gałeczka-TurkiewiczDepartment of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-032 Katowice, Poland.ORCID 0000-0002-4195-6119
Beata ToczylowskaNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, 02-109 Warsaw, Poland.
Dariusz ZioraDepartment of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 40-032 Katowice, Poland.
Medical University of Silesia · PLInstitute of Biocybernetics and Biomedical Engineering · PL

Funding

National Science Centre in Poland 2016/23/N/NZ7/02002
6 · The paper itself

Abstract

(1) Background: Pulmonary rehabilitation (PR) plays a significant therapeutic role for patients with idiopathic interstitial pneumonia (IIP). The study assessed the impact of physical activity on lung function measured by forced oscillation technique (FOT). (2) Methods: The study involved 48 patients with IIP subjected to a 3-week inpatient PR. The control group included IIP patients (n = 44) on a 3-week interval without PR. All patients were assessed at baseline and after 3 weeks of PR by FOT, spirometry, plethysmography, grip strength measurement and the 6-minute walk test. (3) Results: There were no significant changes in FOT measurements in the PR group, except for reduced reactance at 11 Hz, observed in both groups (p < 0.05). Patients who completed PR significantly improved their 6-min walk distance (6MWD) and forced vital capacity (FVC). The change in 6MWD was better in patients with higher baseline reactance (p = 0.045). (4) Conclusions: Patients with IIP benefit from PR by an increased FVC and 6MWD; however, no improvement in FOT values was noticed. Slow disease progression was observed in the study and control groups, as measured by reduced reactance at 11 Hz. Patients with lower baseline reactance limitations achieve better 6MWD improvement.

Indexed as

forced oscillation techniqueidiopathic interstitial pneumoniaspulmonary rehabilitationrespiratory oscillometry

Identifiers

PMID35806942
PMCPMC9267680
OpenAlexW4283526163

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.