ArticleJournal of clinical medicine2022

Does an Adjustable-Loop Device Loosen following ACL Reconstruction with a Hamstring Graft? A Retrospective Study with a Follow-Up of Two Years.

Mohammad Jesan Khan, Naiyer Asif, Mohd Hadi Aziz, Ariz Raza, Shahzad Anwar, Shibili Nuhmani, Ahmad H Alghadir, Masood Khan

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Mohammad Jesan KhanDepartment of Orthopaedic Surgery, Jawaharlal Nehru Medical College Hospital, Aligarh Muslim University, Aligarh 202002, Uttar Pradesh, India.
Naiyer AsifDepartment of Orthopaedic Surgery, Jawaharlal Nehru Medical College Hospital, Aligarh Muslim University, Aligarh 202002, Uttar Pradesh, India.
Mohd Hadi AzizDepartment of Orthopaedic Surgery, Jawaharlal Nehru Medical College Hospital, Aligarh Muslim University, Aligarh 202002, Uttar Pradesh, India.ORCID 0000-0001-7541-5196
Ariz RazaDepartment of Orthopaedic Surgery, Jawaharlal Nehru Medical College Hospital, Aligarh Muslim University, Aligarh 202002, Uttar Pradesh, India.
Shahzad AnwarDepartment of TB and Chest, Jawaharlal Nehru Medical College Hospital, Aligarh Muslim University, Aligarh 202002, Uttar Pradesh, India.
Shibili NuhmaniDepartment of Physical Therapy, College of Applied Medical Sciences, Imam Abdulrahman bin Faisal University, Dammam 34221, Saudi Arabia.ORCID 0000-0002-7868-5113
Ahmad H AlghadirRehabilitation Research Chair, Department of Rehabilitation Sciences, College of Applied Medical Sciences, King Saud University, Riyadh 11433, Saudi Arabia.
Masood KhanRehabilitation Research Chair, Department of Rehabilitation Sciences, College of Applied Medical Sciences, King Saud University, Riyadh 11433, Saudi Arabia.ORCID 0000-0002-8051-142X
Jawaharlal Nehru Medical College Hospital · INKing Saud University · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Arthroscopic anatomic anterior cruciate ligament reconstruction (ACLR) is the gold standard treatment for an ACL tear and requires the use of fixed or adjustable-loop devices to fix a femoral-side graft. Although the adjustable mechanism is designed to provide one-way tensioning, there is a concern that the adjustable loop will loosen and lengthen during cyclic loads, creating graft laxity. The present paper is a retrospective study of patients who underwent ACLR with the fixation of a hamstring graft with an adjustable loop on the femoral side from November 2016 to October 2018. The knee’s functional outcome was evaluated using an International Knee Documentation Committee (IKDC) score, Lysholm score, Lachman test, and pivot shift test. The patients were assessed preoperatively and finally postoperatively after two years of surgery. Thirty-two patients were analyzed. Significant improvement was obtained in the final clinical outcome of the patients. Twenty-seven patients (84.4%) were Lachman negative, and twenty-eight patients (87.5%) were pivot shift test negative, the mean Lysholm score was 96.91, and the IKDC score was 91.47 (p < 0.001). There was no infection, graft failure, or flexion restriction. Arthroscopic ACLR with an adjustable-loop suspensory device is a successful fixation method for femoral-side graft fixation and offers a similar functional outcome as with fixed-loop devices.

Indexed as

adjustable-loop deviceanterior cruciate ligament reconstructionhamstring graft

Identifiers

PMID35806933
PMCPMC9267585
OpenAlexW4283576207

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.