Evidence map›Paper›PMID 35806658›Full record

ArticleMaterials (Basel, Switzerland)2022

The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials.

Saima Qureshi, Lazar Milić, Bojan Petrović, Marija Vejin, Sanja Kojić, Stefan Jarić, Goran Stojanović

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Estimation of wettability of topical fluoride gel on anterior and posterior teeth: AnJournal of advanced pharmaceutical technology & research · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Saima QureshiDepartment of Power, Electronics and Telecommunications, Faculty of Technical Sciences, University of Novi Sad, Fruškogorska, 11, 21000 Novi Sad, Serbia.
Lazar MilićDepartment of Power, Electronics and Telecommunications, Faculty of Technical Sciences, University of Novi Sad, Fruškogorska, 11, 21000 Novi Sad, Serbia.
Bojan PetrovićDepartment of Dentistry, Faculty of Medicine, University of Novi Sad, Hajduk Veljkova, 3, 21000 Novi Sad, Serbia.ORCID 0000-0002-3575-3921
Marija VejinDepartment of Power, Electronics and Telecommunications, Faculty of Technical Sciences, University of Novi Sad, Fruškogorska, 11, 21000 Novi Sad, Serbia.
Sanja KojićDepartment of Power, Electronics and Telecommunications, Faculty of Technical Sciences, University of Novi Sad, Fruškogorska, 11, 21000 Novi Sad, Serbia.ORCID 0000-0002-4092-9733
Stefan JarićInstitute BioSense, University of Novi Sad, Dr. Zorana Đinđića, 1, 21000 Novi Sad, Serbia.ORCID 0000-0001-7933-3542
Goran StojanovićDepartment of Power, Electronics and Telecommunications, Faculty of Technical Sciences, University of Novi Sad, Fruškogorska, 11, 21000 Novi Sad, Serbia.ORCID 0000-0003-2098-189X

Funding

European Commission 872370
6 · The paper itself

Abstract

The aim of this study was to tackle the topic of appropriate recommendations for artificial-saliva and mouthwash usage. The contact angle, pH, and conductivity of two artificial saliva solutions, four mouthwashes, and their mixtures on enamel, glass-ionomer, and composite dental materials were measured. The measurements were conducted with a MATLAB algorithm to minimize human error. The obtained values for the contact angle were in the range from 7.98° to 52.6°, and they showed completely nonlinear and nonuniform behavior for all investigated liquids and on all investigated substrates. Results reveal statistically significant differences among all tested liquids on all investigated substrates (p < 0.05). pH values ranged from 1.54 to 7.01. A wide range of conductivity values were observed, from 1205µS/cm in the saliva-stimulating solution to 6679 mS/cm in the artificial saliva. Spearman’s test showed a moderate positive correlation between the pH and conductivity of the tested fluids (R = 0.7108). A comparison of the data obtained using Image J software and the MATLAB algorithm showed consistency, not exceeding 5% error. When an experiment uses human material and bioactive materials THAT are used in biomedicine as substrates, an additional definition of protocols is highly recommended for future research on this topic.

Indexed as

compositeconductivitycontact angleenamelglass ionomerMATLABsalivawetting

Identifiers

PMID35806658
PMCPMC9267139

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.