Evidence map›Paper›PMID 35806592›Full record

ArticleMaterials (Basel, Switzerland)2022

Rhombohedral Phase Formation in Yttria-Stabilized Zirconia Induced by Dental Technical Tools and Its Impact on Dental Applications.

Markus Wertz, Michael Benno Schmidt, Hieronymus Hoelzig, Maximilian Wagner, Bernd Abel, Gert Kloess, Sebastian Hahnel, Andreas Koenig

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Markus WertzDepartment of Prosthodontics and Material Sciences, Leipzig University, 04103 Leipzig, Germany.ORCID 0000-0002-0319-9153
Michael Benno SchmidtDepartment of Prosthodontics and Material Sciences, Leipzig University, 04103 Leipzig, Germany.
Hieronymus HoelzigInstitute of Mineralogy, Crystallography and Materials Science, Leipzig University, 04275 Leipzig, Germany.
Maximilian WagnerDepartment of Prosthodontics and Material Sciences, Leipzig University, 04103 Leipzig, Germany.
Bernd AbelWilhelm-Ostwald-Institute for Physical and Theoretical Chemistry, 04103 Leipzig, Germany.ORCID 0000-0001-6032-1680
Gert KloessInstitute of Mineralogy, Crystallography and Materials Science, Leipzig University, 04275 Leipzig, Germany.
Sebastian HahnelDepartment of Prosthodontics and Material Sciences, Leipzig University, 04103 Leipzig, Germany.
Andreas KoenigDepartment of Prosthodontics and Material Sciences, Leipzig University, 04103 Leipzig, Germany.ORCID 0000-0002-5617-3707

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the study the influence of different dental technical tools on the surface temperature and phase composition of fixed dental prostheses (FDPs) made of yttria-partially stabilized zirconia polycrystals (3Y-/4Y-/5Y-PSZ) was investigated. FDPs were fabricated by using computer-aided manufacturing (CAM). The FDPs were treated with a contra-angle handpiece equipped with different burs and polishers. The resulting surface temperatures were measured with a thermographic camera, and the resulting phase transformations were investigated by X-ray diffraction and quantified by Rietveld refinement. Processing with burs resulted in no phase transformation, but a preferred orientation shift. Using coarse polisher induced a phase transformation to the rhombohedral phase, while fine polishers produced no relevant phase transformations and no preferred orientation shift. Compared to the monoclinic phase (ca. 9% theoretical volume increase), which is associated with low-temperature degradation (LTD), the rhombohedral phase is much more voluminous (ca. 15% theoretical volume increase) and distorted and, therefore, has a greater degradation potential.

Indexed as

computer-aided manufacturingdental zirconiafixed dental prosthesisphase compositionX-ray diffraction

Identifiers

PMID35806592
PMCPMC9267609

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked