Evidence map›Paper›PMID 35803979›Full record

ArticleScientific reports2022

3D-printed lightweight dorsal skin fold chambers from PEEK reduce chamber-related animal distress.

Wentao Xie, Matthias Lorenz, Friederike Poosch, Rupert Palme, Dietmar Zechner, Brigitte Vollmar, Eberhard Grambow, Daniel Strüder

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

Wentao XieInstitute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany.
Matthias LorenzFaculty of Engineering, Technology, Business and Design, University of Applied Sciences, 23966, Wismar, Germany.
Friederike PooschDepartment of Otorhinolaryngology, Head and Neck Surgery "Otto Koerner", Rostock University Medical Center, 18057, Rostock, Germany.
Rupert PalmeUnit of Physiology, Pathophysiology and Experimental Endocrinology, Department of Biomedical Sciences, University of Veterinary Medicine Vienna, 1210, Vienna, Austria.
Dietmar ZechnerInstitute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany.
Brigitte VollmarInstitute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany.
Eberhard GrambowInstitute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany. eberhard.grambow@med.uni-rostock.de.
Daniel StrüderInstitute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany.
University of Rostock · DEUniversity of Veterinary Medicine Vienna · ATWismar University of Applied Sciences · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The dorsal skinfold chamber is one of the most important in vivo models for repetitive longitudinal assessment of microcirculation and inflammation. This study aimed to refine this model by introducing a new lightweight chamber made from polyetheretherketone (PEEK). Body weight, burrowing activity, distress, faecal corticosterone metabolites and the tilting angle of the chambers were analysed in mice carrying either a standard titanium chamber or a PEEK chamber. Data was obtained before chamber preparation and over a postoperative period of three weeks. In the early postoperative phase, reduced body weight and increased faecal corticosterone metabolites were found in mice with titanium chambers. Chamber tilting and tilting-related complications were reduced in mice with PEEK chambers. The distress score was significantly increased in both groups after chamber preparation, but only returned to preoperative values in mice with PEEK chambers. In summary, we have shown that light chambers reduce animal distress and may extend the maximum dorsal skinfold chamber observation time. Chambers made of PEEK are particularly suitable for this purpose: They are autoclavable, sufficiently stable to withstand rodent bites, inexpensive, and widely available through 3D printing.

Indexed as

CorticosteroneTitaniumAnimalsBenzophenonesBody WeightKetonesMicePolyethylene GlycolsPolymersPrinting, Three-DimensionalBenzophenonesCorticosteroneKetonespolyetheretherketonePolyethylene GlycolsPolymersTitanium

Identifiers

PMID35803979
PMCPMC9270450
OpenAlexW4284885858

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.