Evidence map›Paper›PMID 35802280›Full record

ArticleEJNMMI physics2022

Optimizing acquisition times for total-body positron emission tomography/computed tomography with half-dose

Yibo He, Yushen Gu, Haojun Yu, Bing Wu, Siyang Wang, Hui Tan, Yanyan Cao, Shuguang Chen, Xiuli Sui, Yiqiu Zhang and 1 more

Abstract read
In one paragraph

Article in EJNMMI physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Exploring the feasibility of a 40-minute uptake time for long axial field of view [European journal of nuclear medicine and molecular imaging · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Expert consensus on workflow of PET/CT with long axial field-of-view.European journal of nuclear medicine and molecular imaging · 2025
    Review
  6. Article
  7. Article
  8. Combined whole-body dynamic and static PET/CT with low-dose [European journal of nuclear medicine and molecular imaging · 2024
    Article
  9. Image Quality and Quantitative PET Parameters of Low-Dose [Diagnostics (Basel, Switzerland) · 2023
    Article
  10. Long axial field of view (LAFOV) PET-CT: implementation in static and dynamic oncological studies.European journal of nuclear medicine and molecular imaging · 2023
    Review
  11. Application of the long axial field-of-view PET/CT with low-dose [European journal of nuclear medicine and molecular imaging · 2023
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yibo He *Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
Yushen Gu *Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
Haojun YuShanghai Institute of Medical Imaging, Shanghai, 200032, China.
Bing WuShanghai Institute of Medical Imaging, Shanghai, 200032, China.
Siyang WangShanghai Institute of Medical Imaging, Shanghai, 200032, China.
Hui TanShanghai Institute of Medical Imaging, Shanghai, 200032, China.
Yanyan CaoShanghai Institute of Medical Imaging, Shanghai, 200032, China.
Shuguang ChenShanghai Institute of Medical Imaging, Shanghai, 200032, China.
Xiuli SuiShanghai Institute of Medical Imaging, Shanghai, 200032, China.
Yiqiu ZhangShanghai Institute of Medical Imaging, Shanghai, 200032, China. zhang.yiqiu@zs-hospital.sh.cn.
Hongcheng ShiShanghai Institute of Medical Imaging, Shanghai, 200032, China. shi.hongcheng@zs-hospital.sh.cn.ORCID http://orcid.org/0000-0001-7457-876X

Funding

Clinical Research Plan of SHDC No. SHDC2020CR3079BClinical Research Project of Zhongshan Hospital, Fudan University 2020ZSLC63Science and Technology Committee of Shanghai Municipality 20DZ2201800Shanghai Municipal Commission of Economy and Informatization 201901014Shanghai Municipal Key Clinical Specialty shslczdzk03401The Youth Medical Talents-Medical Imaging Practitioner Program of Shanghai "Rising Stars of Medical Talent" Youth Development Program SHWRS[2020]_087
6 · The paper itself

Abstract

backgroundThe present study aimed to explore the boundary of acquisition time and propose an optimized acquisition time range for total-body positron emission tomography (PET)/computed tomography (CT) oncological imaging using half-dose (1.85 MBq/kg)

methodsIn this retrospective study based on a total-body PET system (uEXPLORER), an exploration cohort (October 2019-December 2019) of 46 oncology patients was first studied. The acquisition time for all patients was 15 min, and the acquired images were reconstructed and further split into 15-, 8-, 5-, 3-, 2-, and 1-min duration groups (abbreviated as G15, G8, G5, G3, G2, and G1). The image quality and lesion detectability of reconstructed PET images with different acquisition times were evaluated subjectively (5-point scale, lesion detection rate) and objectively (standardized uptake values, tumor-to-background ratio). In the same way, the initial optimized acquisition times were further validated in a cohort of 147 oncology patients (December 2019-June 2021) by using the Gs images (the images obtained using the 15- and 10-min acquisition times) as controls.

resultsIn the exploration cohort, the subjective scores for G1, G2, G3, G5, and G8 images were 2.0 ± 0.2, 2.9 ± 0.3, 3.0 ± 0.0, 3.9 ± 0.2, and 4.2 ± 0.4, respectively. Two cases in G1 were rated as 1 point. No significant difference in scores was observed between G5 and G8 (p > 0.99). In general, groups with a longer acquisition time showed lower background uptake and lesion conspicuity. Compared with G15, lesion detection rate significantly reduced to 85.3% in G1 (p < 0.05). In the validation cohort, the subjective score was 3.0 ± 0.2 for G2, 3.0 ± 0.1 for G3, 3.6 ± 0.5 for G5, 4.0 ± 0.3 for G8, and 4.4 ± 0.5 for Gs. Only the scores between G2 and G3 were not significantly different (p > 0.99). The detection rates (204 lesions) significantly reduced to 94.1-90.2% in G3 and G2 (all p < 0.05).

conclusionA 2-min acquisition time provided acceptable performance in certain groups and specific medical situations. And protocols with acquisition times ≥ 5 min could provide comparable lesion detectability as regular protocols, showing better compatibility and feasibility with clinical practice.

Indexed as

Acquisition timesHalf-doseImage qualityLesion detectabilityTotal-body PET/CT

Identifiers

PMID35802280
PMCPMC9270529

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.