Evidence map›Paper›PMID 35800631›Full record

ArticleSpine surgery and related research2022

Usefulness of Preoperative Planning by Three-Dimensional Planning Software for Pedicle Screw Placement in Thoracolumbar Surgeries:

Tomonori Ozaki, Kentaro Yamada, Hiroaki Nakamura

Abstract read
In one paragraph

Article in Spine surgery and related research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tomonori OzakiDepartment of Orthopaedic Surgery, Fuchu Hospital, Izumi, Japan.
Kentaro YamadaDepartment of Orthopaedic Surgery, Fuchu Hospital, Izumi, Japan.
Hiroaki NakamuraDepartment of Orthopaedic Surgery, Osaka Metropolitan University, Osaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: A number of imaging technologies have been developed to reduce the risk of pedicle screw (PS) misplacement. For example, preoperative three-dimensional (3D) planning can reportedly enhance implant placement accuracy in some orthopedic surgeries. However, no study has investigated the effect of preoperative 3D planning on PS placement without intraoperative 3D navigation. Thus, in this study, we aim to examine the accuracy of PS placement and identify the risk factors for PS misplacement in thoracolumbar surgeries performed using preoperative 3D planning software with intraoperative fluoroscopic guidance in a retrospective study. Methods: In total, 25 consecutive patients (197 PSs) underwent thoracic or lumbar spinal fusion surgeries using preoperative 3D planning with intraoperative fluoroscopic guidance. PS misplacement was graded based on the degree of perforation (Grade 0, no perforation; Grade 1, <2 mm; Grade 2, 2-4 mm; Grade 3, >4 mm) observed in postoperative computed tomography (CT). Deviations between planned and actual PSs were evaluated by matching preoperative and postoperative CT volume images for each vertebra. Results: The overall PS misplacement rate was 6.6% (Grade 1: 4.0%, Grade 2: 1.5%, Grade 3: 1.0%). The median linear deviations of PS entry points between planned and actual locations were determined to be 3.3 mm and 3.3 mm for the horizontal and vertical axes, respectively. The median angular deviations of the PS axis were 6.2° and 4.5° for the transverse and sagittal planes, respectively. Multivariate analysis revealed that horizontal deviation of the PS entry point was the sole factor associated with Grade ≥1 PS misplacement (odds ratio=2.47, p<0.001). Conclusions: Preoperative 3D planning software without intraoperative 3D navigation was able to achieve a relatively low PS misplacement ratio among the reported ratio of conventional techniques without navigation. Surgeons should carefully ensure that the entry point is consistent with preoperative planning, especially in the mediolateral direction to avoid misplacement in this method.

Indexed as

AccuracyComputed tomographyDeviationMisplacementPedicle screwPlanning softwareRisk factorThree-dimensional

Identifiers

PMID35800631
PMCPMC9200427

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.