ArticlePakistan journal of medical sciences
Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population.
Article in Pakistan journal of medical sciences. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Validity and reliability of hand-held dynamometers in hip, knee, and ankle strength testing in healthy adults: A systematic review and meta-analysis.Hong Kong physiotherapy journal : official publication of the Hong Kong Physiotherapy Association Limited = Wu li chih liao · 2026Article
- Effects of aquatic therapy vs. standard care on gluteal muscle morphology and function in individuals with chronic low back pain: a randomized controlled trial.BMC sports science, medicine & rehabilitation · 2026Article
- Article
- Article
- The Single-Leg Wall Squat Test: An Assessment of Functional Lower Extremity Endurance in University Students.International journal of sports physical therapy · 2025Article
- Comparative Efficacy of Quadratus Lumborum Muscle Energy Technique with Gluteus Medius Strengthening Versus Gluteus Medius Strengthening Alone in Sacroiliac Joint Dysfunction: A Randomized Controlled Trial.Diagnostics (Basel, Switzerland) · 2024Article
- Selected morphological, cardiovascular and neuromuscular risk profiles among asymptomatic sedentary men performing Islamic prayer.BMJ open sport & exercise medicine · 2024Article
- Effect of aquatic exercise versus standard care on paraspinal and gluteal muscles morphology in individuals with chronic low back pain: a randomized controlled trial protocol.BMC musculoskeletal disorders · 2023Article
- Article
- Gluteus medius muscle strengthening exercise effects on medial longitudinal arch height in individuals with flexible flatfoot: a randomized controlled trial.Journal of exercise rehabilitation · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: To determine the inter-rater and intra-rater reliability of the hand-held dynamometer in measuring isometric gluteus medius muscle strength in asymptomatic healthy population. Methods: It was a cross sectional study conducted at the department of physiotherapy, Sindh Institute of Physical Medicine and Rehabilitation from March 2021 to April 2021. Thirty healthy subjects aged 18 to 25 years of both sexes and no previous or current complaints of hip or knee pain were included through non-probability purposive sampling technique. The strength of the unilateral isometric gluteus medius muscle was measured using a hand-held dynamometer by two raters at the same day and a week later. Pearson Correlation coefficient was calculated to see the relationship of muscle strength measured by each rater within and between day's sessions. Intra-class correlation was calculated with 95% confidence interval and Standard error of measurements using reliability analysis. Results: In the present study there were thirty participants studied by two raters, the mean age of participants was 21.53 (SD=±1.40) years, the mean BMI was 24.05 (SD=±1.12) kg/m2 and 70% participants were female and 30% were males. This study showed the mean muscle measurement of participants within days was 12.92 (SD=±0.94), with intra-class correlation ICC (2,2) 0.94 and SEM 0.12 and mean muscle measurement of patients between days was 12.99 (SD=±0.91), with intra-class correlation ICC (2,2) 0.90 and SEM 0.12.. Conclusion: Hand-held dynamometer has shown excellent inter-rater and intra-rater reliability in measuring isometric strength of Gluteus Medius muscle among healthy population. It is convenient to be used in clinical settings and can be a useful outcome tool to assess strength in interventional studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.