Evidence map›Paper›PMID 35799544›Full record

ArticleNeural regeneration research2023

Electrodeposition of chitosan/graphene oxide conduit to enhance peripheral nerve regeneration.

Ya-Nan Zhao, Ping Wu, Zi-Yuan Zhao, Fei-Xiang Chen, Ao Xiao, Zhi-Yi Yue, Xin-Wei Han, Yong Zheng, Yun Chen

Open access · goldAbstract read
In one paragraph

Article in Neural regeneration research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 29 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Ya-Nan ZhaoDepartment of Biomedical Engineering and Hubei Province Key Laboratory of Allergy and Immune Related Disease, School of Basic Medical Sciences, Wuhan University, Wuhan; Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China.
Ping WuDepartment of Biomedical Engineering and Hubei Province Key Laboratory of Allergy and Immune Related Disease, School of Basic Medical Sciences, Wuhan University, Wuhan, Hubei Province, China.
Zi-Yuan ZhaoClinical Medical College, Hubei University of Science and Technology, Xianning, Hubei Province, China.
Fei-Xiang ChenDepartment of Biomedical Engineering and Hubei Province Key Laboratory of Allergy and Immune Related Disease, School of Basic Medical Sciences, Wuhan University, Wuhan, Hubei Province, China.
Ao XiaoDepartment of Biomedical Engineering and Hubei Province Key Laboratory of Allergy and Immune Related Disease, School of Basic Medical Sciences, Wuhan University, Wuhan, Hubei Province, China.
Zhi-Yi YueDepartment of Biomedical Engineering and Hubei Province Key Laboratory of Allergy and Immune Related Disease, School of Basic Medical Sciences, Wuhan University, Wuhan, Hubei Province, China.
Xin-Wei HanDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China.
Yong ZhengDepartment of Biomedical Engineering and Hubei Province Key Laboratory of Allergy and Immune Related Disease, School of Basic Medical Sciences, Wuhan University, Wuhan, Hubei Province, China.
Yun ChenDepartment of Biomedical Engineering and Hubei Province Key Laboratory of Allergy and Immune Related Disease, School of Basic Medical Sciences, Wuhan University, Wuhan, Hubei Province, China.
Wuhan University · CNFirst Affiliated Hospital of Zhengzhou University · CNHubei University of Science and Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Currently available commercial nerve guidance conduits have been applied in the repair of peripheral nerve defects. However, a conduit exhibiting good biocompatibility remains to be developed. In this work, a series of chitosan/graphene oxide (GO) films with concentrations of GO varying from 0-1 wt% (collectively referred to as CHGF-n) were prepared by an electrodeposition technique. The effects of CHGF-n on proliferation and adhesion abilities of Schwann cells were evaluated. The results showed that Schwann cells exhibited elongated spindle shapes and upregulated expression of nerve regeneration-related factors such as Krox20 (a key myelination factor), Zeb2 (essential for Schwann cell differentiation, myelination, and nerve repair), and transforming growth factor β (a cytokine with regenerative functions). In addition, a nerve guidance conduit with a GO content of 0.25% (CHGFC-0.25) was implanted to repair a 10-mm sciatic nerve defect in rats. The results indicated improvements in sciatic functional index, electrophysiology, and sciatic nerve and gastrocnemius muscle histology compared with the CHGFC-0 group, and similar outcomes to the autograft group. In conclusion, we provide a candidate method for the repair of peripheral nerve defects using free-standing chitosan/GO nerve conduits produced by electrodeposition.

Indexed as

chitosanelectrodepositionfree-standinggraphene oxidenerve conduitnerve factorsSchwann cellstissue engineerin

Identifiers

PMID35799544
PMCPMC9241416
OpenAlexW4229023793

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.