Evidence map›Paper›PMID 35798998›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

Navigation guidance for ventricular septal defect closure in heart phantoms.

Gerardo Tibamoso-Pedraza, Sarah Amouri, Victor Molina, Iñaki Navarro, Marie-Josée Raboisson, Joaquim Miró, Chantale Lapierre, Sylvie Ratté, Luc Duong

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Gerardo Tibamoso-PedrazaInterventional Imaging Lab, Department of Software and IT Engineering, École de technologie supérieure, 1100, Notre-Dame West, Montréal, H3C 1K3, Québec, Canada. gerardo.tibamoso-pedraza.1@etsmtl.net.ORCID http://orcid.org/0000-0002-6160-8285
Sarah AmouriInterventional Imaging Lab, Department of Software and IT Engineering, École de technologie supérieure, 1100, Notre-Dame West, Montréal, H3C 1K3, Québec, Canada.
Victor MolinaCardiology, Department of Pediatrics, CHU Sainte-Justine, 3175, chemin de la Côte-Sainte-Catherine, Montréal, H3T 1C5, Québec, Canada.
Iñaki NavarroCardiology, Department of Pediatrics, CHU Sainte-Justine, 3175, chemin de la Côte-Sainte-Catherine, Montréal, H3T 1C5, Québec, Canada.
Marie-Josée RaboissonCardiology, Department of Pediatrics, CHU Sainte-Justine, 3175, chemin de la Côte-Sainte-Catherine, Montréal, H3T 1C5, Québec, Canada.
Joaquim MiróCardiology, Department of Pediatrics, CHU Sainte-Justine, 3175, chemin de la Côte-Sainte-Catherine, Montréal, H3T 1C5, Québec, Canada.
Chantale LapierreCardiology, Department of Pediatrics, CHU Sainte-Justine, 3175, chemin de la Côte-Sainte-Catherine, Montréal, H3T 1C5, Québec, Canada.
Sylvie RattéInterventional Imaging Lab, Department of Software and IT Engineering, École de technologie supérieure, 1100, Notre-Dame West, Montréal, H3C 1K3, Québec, Canada.
Luc DuongInterventional Imaging Lab, Department of Software and IT Engineering, École de technologie supérieure, 1100, Notre-Dame West, Montréal, H3C 1K3, Québec, Canada.
Centre Hospitalier Universitaire Sainte-Justine · CAÉcole de Technologie Supérieure · CA

Funding

Fonds de Recherche du Québec - Nature et Technologies File: 276451
6 · The paper itself

Abstract

purposeTransesophageal echocardiography (TEE) is the preferred imaging modality in a hybrid procedure used to close ventricular septal defects (VSDs). However, the limited field of view of TEE hinders the maneuvering of surgical instruments inside the beating heart. This study evaluates the accuracy of a method that aims to support navigation guidance in the hybrid procedure.

methodsA cardiologist maneuvered a needle to puncture the patient's heart and to access a VSD, guided by information displayed in a virtual environment. The information displayed included a model of the patient's heart and a virtual needle that reproduced the position and orientation of the real needle in real time. The physical and the virtual worlds were calibrated with a landmark registration and an iterative closest point algorithms, using an electromagnetic measurement system (EMS). For experiments, we developed a setup that included heart phantoms representing the patient's heart.

resultsExperimental results from two pediatric cases studied suggested that the information provided for guidance was accurate enough when the landmark registration algorithm was fed with coordinates of seven points clearly identified on the surfaces of the physical and virtual hearts. Indeed, with a registration error of 2.28 mm RMS, it was possible to successfully access two VSDs (6.2 mm and 6.3 mm in diameter) in all the attempts with a needle (5 attempts) and a guidewire (7 attempts).

conclusionWe found that information provided in a virtual environment facilitates guidance in the hybrid procedure for VSD closure. A clear identification of anatomical details in the heart surfaces is key to the accuracy of the procedure.

Indexed as

Heart Septal Defects, VentricularChildEchocardiography, TransesophagealHumansInfantPhantoms, ImagingTreatment OutcomeHeart phantomsPerventricular interventionTransesophageal echocardiographyVentricular septal defect

Identifiers

PMID35798998
OpenAlexW4284886939

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.