Evidence map›Paper›PMID 35796934›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2023

Low-energy (360 J) radiofrequency catheter ablation using moderate power - short duration: proof of concept based on in silico modeling.

Juan J Pérez, Robert D'Angelo, Ana González-Suárez, Hiroshi Nakagawa, Enrique Berjano, Andre d'Avila

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Next-generation atrial fibrillation ablation: clinical performance of pulsed-field ablation and very high-power short-duration radiofrequency.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2024
    Article
  2. Article
  3. Article
  4. A new variation of RF ablation: moderate-power short-duration.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Juan J Pérez *BioMIT, Department of Electronic Engineering, Universitat Politècnica de València, Valencia, Spain.
Robert D'Angelo *Division of Cardiovascular Medicine, Harvard-Thorndike Electrophysiology Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, 02215, USA.
Ana González-SuárezElectrical and Electronic Engineering, National University of Ireland Galway, Galway, Ireland.
Hiroshi NakagawaDepartment of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA.
Enrique BerjanoBioMIT, Department of Electronic Engineering, Universitat Politècnica de València, Valencia, Spain.
Andre d'AvilaDivision of Cardiovascular Medicine, Harvard-Thorndike Electrophysiology Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, 02215, USA. adavila@bidmc.harvard.edu.ORCID http://orcid.org/0000-0001-8769-1411

Funding

Ministerio de Ciencia e Innovación RTI2018-094357-B-C21
6 · The paper itself

Abstract

backgroundPilot clinical studies suggest that very high power-very short duration (vHPvSD, 90 W/4 s, 360 J energy) is a feasible and safe technique for ablation of atrial fibrillation (AF), compared with standard applications using moderate power-moderate duration (30 W/30 s, 900 J energy). However, it is unclear whether alternate power and duration settings for the delivery of the same total energy would result in similar lesion formation. This study compares temperature dynamics and lesion size at different power-duration settings for the delivery of equivalent total energy (360 J).

methodsAn in silico model of radiofrequency (RF) ablation was created using the Arrhenius function to estimate lesion size under different power-duration settings with energy balanced at 360 J: 30 W/12 s (MPSD), 50 W/7.2 s (HPSD), and 90 W/4 s (vHPvSD). Three catheter orientations were considered: parallel, 45°, and perpendicular.

resultsIn homogenous tissue, vHPvSD and HPSD produced similar size lesions independent of catheter orientation, both of which were slightly larger than MPSD (lesion size 0.1 mm deeper, ~ 0.7 mm wider, and ~ 25 mm

conclusionAblation for AF using MPSD or HPSD may be a feasible alternative to vHPvSD ablation given similar size lesions with similar total energy delivery (360 J). Lower absolute tissue temperature and slower heating may reduce risk of collateral tissue injury and steam pops associated with vHPvSD and longer applications using moderate power.

Indexed as

Atrial FibrillationCatheter AblationPulmonary VeinsRadiofrequency AblationComputer SimulationHumansSteamTreatment OutcomeSteamAtrial fibrillationHigh power–short durationModerate powerRadiofrequency ablation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.