Evidence map›Paper›PMID 35791381›Full record

ArticleBiophysical reviews2022

Synchrotron X-ray biosample imaging: opportunities and challenges.

Gabriela Sena, Gabriel Fidalgo, Katrine Paiva, Renan Barcelos, Liebert Parreiras Nogueira, Marcos Vinícius Colaço, Marcelo Salabert Gonzalez, Patricia Azambuja, Gustavo Colaço, Helio Ricardo da Silva and 2 more

Open access · greenAbstract read
In one paragraph

Article in Biophysical reviews, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 6 institutions in 2 countries.

Gabriela SenaLaboratory of Applied Physics to Biomedical Sciences, Physics Institute, State University of Rio de Janeiro, Rio de Janeiro, Brazil.
Gabriel FidalgoLaboratory of Applied Physics to Biomedical Sciences, Physics Institute, State University of Rio de Janeiro, Rio de Janeiro, Brazil.
Katrine PaivaLaboratory of Applied Physics to Biomedical Sciences, Physics Institute, State University of Rio de Janeiro, Rio de Janeiro, Brazil.
Renan BarcelosLaboratory of Applied Physics to Biomedical Sciences, Physics Institute, State University of Rio de Janeiro, Rio de Janeiro, Brazil.
Liebert Parreiras NogueiraOral Research Laboratory (ORL), Institute of Clinical Dentistry, University of Oslo, Oslo, Norway.
Marcos Vinícius ColaçoLaboratory of Applied Physics to Biomedical Sciences, Physics Institute, State University of Rio de Janeiro, Rio de Janeiro, Brazil.
Marcelo Salabert GonzalezPost-Graduate Program in Science and Biotechnology, Federal University Fluminense, Rio de Janeiro, Brazil.
Patricia AzambujaPost-Graduate Program in Science and Biotechnology, Federal University Fluminense, Rio de Janeiro, Brazil.
Gustavo ColaçoLaboratory of Herpetology, Federal Rural University of Rio de Janeiro, Rio de Janeiro, Brazil.
Helio Ricardo da SilvaLaboratory of Herpetology, Federal Rural University of Rio de Janeiro, Rio de Janeiro, Brazil.
Anderson Alvarenga de Moura MenesesLaboratory of Computational Intelligence, Federal University of Western Pará, Santarém, Pará, Brazil.
Regina Cély BarrosoLaboratory of Applied Physics to Biomedical Sciences, Physics Institute, State University of Rio de Janeiro, Rio de Janeiro, Brazil.ORCID 0000-0001-6348-694X
Universidade do Estado do Rio de Janeiro · BRUniversidade Federal do Rio de Janeiro · BRUniversidade Federal Fluminense · BRUniversidade Federal Rural do Rio de Janeiro · BRUniversidade Federal do Oeste do Pará · BRUniversity of Oslo · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Synchrotron radiation phase-contrast microtomography is sensitive to low attenuating tissues, giving an alternative visualisation of the sample and being useful for investigating microstructure inside biological specimens without staining them with a contrast medium. The phase-contrast technique has been widely used in the scientific community, as it is a technique associated with radiography and microscopy and able to enhance contrast in soft tissues, specifically at the edges, showing details that could not be seen by the absorption technique. This work aims to show the ability of synchrotron-based phase-contrast microtomography for the visualisation of soft tissues and hard internal structures of millimetre-sized biological organisms. Case studies of the anatomy of

Identifiers

PMID35791381
PMCPMC9250583
OpenAlexW4281608708

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked