Observational studyBMC musculoskeletal disorders2022
Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study.
Observational study in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- Biomechanical effects of lateral pedicle wall violation and subsequent screw redirection on pedicle screw anchorage.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Sensorless Based Haptic Feedback Integration In Robot-assisted Pedicle Screw Insertion For Lumbar Spine Surgery: A preliminary cadaveric study.Computational and structural biotechnology journal · 2024Article
- AR-Supported Supervision of Conditional Autonomous Robots: Considerations for Pedicle Screw Placement in the Future.Journal of imaging · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe pedicle screw system is widely used in spine surgery, and it provides rigid fixation and leads to successful subsequent deformity correction and bony fusion. The standard imaging technique for pedicle screw insertion is two-dimensional images obtained from C-arm-type X-ray fluoroscopy. Artis Zeego is an emerging intraoperative imaging technique that can provide conventional two-dimensional fluoroscopic images and rapid three-dimensional fluoroscopic computed tomography reconstruction imaging. The aim of this study is to compare the insertion accuracies of PS placement using Artis Zeego and conventional 2D X-ray fluoroscopy.
methodsIn this study, we retrospectively reviewed the postoperative images of thoracolumbar fusion patients who underwent surgery using pedicle screws between 2013 and 2018. Pedicle screw malplacement was assessed using a four-grade classification by Rao et al. Misplacement rates were compared between pedicle screws assisted with Artis Zeego and two-dimensional fluoroscopy.
resultsA total of 1107 pedicle screws in 153 patients were inserted using Artis Zeego, and 427 pedicle screws in 80 patients were inserted using fluoroscopy. The overall perforation rate was 4.2% (46 perforations of 1106 pedicle screws) in the Artis Zeego group and 7.7% (33 perforations of 427 pedicle screws) in the fluoroscopy group. In the Artis Zeego group, 43 (3.9%) screws were classified as grade 1, and three (0.3%) screws were classified as grade 2. In the fluoroscopy group, 21 (4.9%) screws were classified as grade 1, 10 (2.3%) screws were classified as grade 2, and 2 (0.5%) screws were classified as grade 3. The use of Artis Zeego was associated with a significantly lower screw malplacement rate than was the use of fluoroscopy (p < 0.001).
conclusionsOur results demonstrated that pedicle screw placement with Artis Zeego was associated with a lower malplacement rate than was conventional two-dimensional fluoroscopy. No severe malplacement was observed in the Artis Zeego group. Thus, Artis Zeego could be a good option for improving pedicle screw accuracy.