Evidence map›Paper›PMID 35790941›Full record

Observational studyBMC ophthalmology2022

Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study.

Lingling Niu, Zhe Zhang, Huamao Miao, Jing Zhao, Meiyan Li, Ji C He, Peijun Yao, Xingtao Zhou

Abstract readObservational Study
In one paragraph

Observational study in BMC ophthalmology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Visual outcomes of implantable Collamer lens and laser-assistedInternational journal of ophthalmology · 2026
    Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lingling Niu *Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China.
Zhe Zhang *Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China.
Huamao MiaoDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China.
Jing ZhaoDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China.
Meiyan LiDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China.
Ji C HeNew England College of Optometry, Boston, MA, USA.
Peijun YaoDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China. pjyao@hotmail.com.
Xingtao ZhouDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, China. doctzhouxingtao@163.com.

Funding

Clinical Research Plan of SHDC SHDC2020CR1043BJoint research project of new frontier technology in municipal hospitals SHDC12018103National Natural Science Foundation of China 81770955Project of Shanghai Science and Technology 20410710100Project of Shanghai Xuhui District Science and Technology 2020-015Research Project Grant of Shanghai Municipal Health Commission 202040285
6 · The paper itself

Abstract

backgroundThe central hole of the Visian Implantable Collamer Lens (ICL V4c) provides a reference to observe its tilt or decentration. This study aimed to investigate the tilt and decentration effects of ICL V4c on visual quality after implantation.

methodsA total of 135 eyes from 69 patients who underwent ICL V4c implantation were included in this study. Evaluation of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and aberrations were performed 6-months postoperatively. The anterior segment parameters were collected using CASIA2 anterior segment-optical coherence tomography, tilt and decentration of ICL V4c were analyzed using MATLAB software. All patients received questionnaires to investigate the visual quality postoperatively.

resultsThe safety and effectiveness were 1.18 ± 0.17 and 1.11 ± 0.18, respectively. No significant changes were observed regarding higher-order and spherical aberrations after the operation; however, coma and trefoil significantly increased compared to preoperative values. The average total decentration and tilt was 0.21 ± 0.12 mm and 2.54 ± 1.00°, respectively. Horizontal, vertical, and total values of tilt and decentration were not significantly associated with postoperative CDVA, UDVA, and aberrations. The most common visual symptom was halo, and 97.04% of patients had a satisfaction score ≥ 8. The total or horizontal tilt was significantly positively correlated with the frequency, severity, and bothersome scores from the questionnaires.

conclusionsICL V4c implantation can obtain high visual quality and patient satisfaction. Although the degree of tilt and decentration after ICL V4c implantation was small, a positive effect on subjective visual quality was observed.

Indexed as

MyopiaPhakic Intraocular LensesHumansLens Implantation, IntraocularTomography, Optical CoherenceVisual AcuityDecentrationImplantable Collamer LensMyopiaTiltVisual quality

Identifiers

PMID35790941
PMCPMC9254425

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.